Guard Cartridges<br />

L C A C C E S S O R I E S<br />

Prep-Guard Columns<br />

• Excellent retention of soluble and particulate<br />

contaminants<br />

• No holder required<br />

Alltech’s Prep-Guard protects your valuable<br />

preparative HP<strong>LC</strong> columns from damaging mobile phases<br />

and sample contaminants without changing your<br />

separation. Columns last longer and performance is more<br />

consistent. Troubleshooting is made easier when peak<br />

shapes begin to deteriorate or backpressures increase<br />

by simply replacing the guard as a first step in restoring<br />

system performance.<br />

Every Prep-Guard is individually packed and pressure<br />

tested to ensure a consistent, high quality product every<br />

time. Connect the Prep-Guard to the column using<br />

Alltech’s Direct-Connect column coupler (Figure 1) or<br />

with fittings and tubing (Figure 2). All of our most<br />

popular prep column packings are offered in a Prep-<br />

Guard format. Fast delivery on custom Prep-Guard <br />

Columns is available for media not shown, or use one of<br />

the “general purpose” packings to accommodate a wide<br />

range of C18 or Silica prep columns.<br />

Prep-Guard Column Specifications<br />

Dimensions:<br />

7mm i.d. x 33mm L<br />

Wetted Materials: Stainless Steel<br />

Max Pressure:<br />

5000psig<br />

Connections:<br />

10-32 UNF<br />

For Use With:<br />

10–25mm i.d. HP<strong>LC</strong> columns<br />

Comments:<br />

Requires Coupler<br />

3806<br />

PREP-GUARD COLUMNS<br />

ALLTECH PACKING PARTICLE SIZE PART NO. PRICE<br />

Alltima C18 10µm 970203<br />

Alltima Silica 10µm 970204<br />

Prevail C18 10µm 970211<br />

Prevail Silica 10µm 970212<br />

Apollo C18 10µm 970205<br />

Apollo Silica 10µm 970206<br />

ProSphere C18 - 300Å 10µm 970213<br />

ProSphere C18 - 100Å 10µm 970221<br />

ProSphere C4 - 300Å 10µm 970214<br />

ProSphere P-PREP 5µm 970220<br />

Econosphere C18 10µm 970209<br />

Econosphere Silica 10µm 970210<br />

General Purpose C18 10µm 970200<br />

General Purpose Silica 10µm 970202<br />

Custom Prep-Guard Any C-6000PG CALL<br />

Figure 1 - Connect with Direct-Connect <br />

coupler. (Part No. 28195)<br />

Figure 2 - Connect with fittings and tubing.<br />

(Part No. 9549)<br />

6286<br />

6285<br />

208<br />

PREP-GUARD ACCESSORIES<br />

DESCRIPTION PART NO. PRICE<br />

Direct-Connect Column Coupler 28195<br />

In-Line Connector 9549<br />

© Copyright 2004 Alltech Associates, Inc.<br />

How Often Should I Change my<br />

Guard Column?<br />

Ideally you want to change a<br />

guard before it becomes saturated.<br />

Obviously, this is difficult to judge,<br />

which leaves the option to either<br />

change at a predetermined time<br />

interval (i.e. every week), or use the<br />

chromatography as a gauge. Peak<br />

shape deterioration and backpressure<br />

increases are visual reminders.<br />

Contact your Alltech office or distributor for current or local prices.