Mobile Phase Handling<br />

L C A C C E S S O R I E S<br />

Alltech Solvent Recycler 3000<br />

• Recycles – Reduces mobile phase purchase and<br />

disposal costs<br />

• Validates – Generates audit trail for GMP, GLP, and<br />

ISO-9000 compliance<br />

• Cleans - AutoClean accessory reduces HP<strong>LC</strong> system<br />

maintenance and down-time<br />

Alltech’s Solvent Recycler 3000 potentially reduces<br />

solvent use by more than 90%. It also helps you comply<br />

with regulatory and quality guidelines with a Validation<br />

Output that records the Recycler’s function. And, the<br />

optional Solvent Recycler 3000’s AutoClean Accessory<br />

reduces maintenance and down-time by automatically<br />

rinsing and re-equilibrating your HP<strong>LC</strong> system.<br />

During an isocratic HP<strong>LC</strong> analysis, the vast majority<br />

of the solvent leaving the detector is clean mobile phase<br />

eluting between peaks. Only those portions containing<br />

sample components (peaks) are actually contaminated.<br />

The Solvent Recycler 3000 throws away only the<br />

contaminated waste and returns the clean mobile phase<br />

to your reservoir. You purchase less solvent, spend less<br />

time preparing mobile phase, and dispose of less waste.<br />

In most cases, the Solvent Recycler 3000 will save you<br />

more than four times its purchase price every year you<br />

use it!<br />

How It Works<br />

The recycling function is accomplished with a Recycle<br />

Valve installed downstream from the detector (Figure 1).<br />

A Control Module uses the detector signal to identify<br />

contaminated mobile phase. When peaks are eluting,<br />

detector effluent goes to waste. Between peaks, clean<br />

mobile phase is sent back to the reservoir (Figure 2).<br />

User selectable parameters allow you to customize<br />

operation to your system and methods. You choose the<br />

minimum threshold which will divert flow to waste, as<br />

well as a delay time to allow the detector outlet line<br />

to be thoroughly flushed before returning flow to your<br />

mobile phase reservoir.<br />

Validation Output<br />

The Model 3000 Solvent Recycler features a Validation<br />

Output to help you comply with regulatory, GMP, GLP,<br />

or ISO-9000 requirements. The Validation Output sends<br />

an auditable data trail to any standard recording device,<br />

giving you a continuous documentation of Recycler<br />

operation. This operational record is a copy of your<br />

chromatographic signal with “waste” and “recycle” tick<br />

marks superimposed at the point of valve switching<br />

(Figure 3). The validation signal is separate from the<br />

one used by the integrator or data system, maintaining<br />

the integrity of your analytical results.<br />

AutoClean Accessory<br />

An optional AutoClean Valve saves even more money<br />

by automatically cleaning the HP<strong>LC</strong> system at the end<br />

of an analysis. Damaging buffers and strongly retained<br />

impurities are removed extending column, pump seal,<br />

and check-valve lifetimes. By controlling the cleaning<br />

function through the recycler, all wash solvents are<br />

automatically diverted to waste, guaranteeing mobilephase<br />

purity.<br />

The AutoClean Valve is installed on your pump’s<br />

inlet line. At the end of an analysis, your autosampler<br />

or system controller signals AutoClean to deliver<br />

wash solvent to the pump. You choose whether to reequilibrate<br />

with mobile phase and/or shut down the<br />

pump. Purchase AutoClean when you buy the Solvent<br />

Recycler 3000, or add it later as your needs expand.<br />

Solvent Recycler 3000 Specifications<br />

Power:<br />

90-240VAC, 50/60 Hz<br />

Display:<br />

Backlit <strong>LC</strong>D, 2-Line x 24-Character<br />

Wetted Parts: PEEK and Teflon ®<br />

Maximum Flow*: 50mL/min (as supplied with 1/16"<br />

tubing on each port)<br />

Recycle Valve Fittings: 1/16", 1/4-28 Flange-Free<br />

AutoClean Valve Fittings: 1/8", 1/4-28 Flange-Free<br />

Analog Input:<br />

10mV, 100mV, 400mV, 1V, or 10V<br />

Dimensions:<br />

13" L x 7.5" W x 2.5" H<br />

(33cm x 19cm x 6.35cm)<br />

Warranty:<br />

Control Module - 3 years<br />

Valves - 1 year<br />

*Maximum flow with short, 1/8" tubing on each port is 250mL/min.<br />

4384<br />

Be Sure You Start with<br />

Clean Mobile Phase.<br />

Use Alltech Vacuum filtration<br />

Systems to filter mobile phase<br />

in the most convenient manner.<br />

See page 245 for details.<br />

1761<br />

250<br />

© Copyright 2004 Alltech Associates, Inc.<br />

Contact your Alltech office or distributor for current or local prices.