19.04.2015 Views

LC Accessories

LC Accessories

LC Accessories

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

L C A C C E S S O R I E S<br />

Pump <strong>Accessories</strong><br />

PEEK Mixing Tee<br />

• Better mixing than a<br />

conventional tee<br />

• Inert, metal-free construction<br />

• Ideal for high-pressure<br />

gradient mixing<br />

Better mixing is the result<br />

5616<br />

of the turbulence generated by the angled ports and<br />

the flow through a PAT (PEEK alloyed with TFE) filter<br />

element. Solvent streams mix more thoroughly than<br />

with a conventional tee. This reduces baseline noise and<br />

improves high pressure gradient mixing or post-column<br />

reactions. Solvents contact PEEK and the PAT filter,<br />

providing a biocompatible, inert, and metal-free flow<br />

path. This tee has a 2.5µL internal volume, a pressure<br />

limit of 6000psig, and comes with fittings and ferrules.<br />

<br />

<br />

<br />

Toroid Mixer<br />

• High efficiency mixer for<br />

preparative chromatography<br />

• Precise and reliable<br />

© Copyright 2004 Alltech Associates, Inc.<br />

<br />

<br />

PEEK MIXING TEE<br />

<br />

<br />

<br />

<br />

DESCRIPTION QTY. PART NO. PRICE<br />

Mixing Tee with Fittings ea 32157<br />

Replacement Fittings 5 35752<br />

Replacement Ferrules 5 35730<br />

The unique design of the<br />

4708<br />

Toroid Mixer extends the mixing<br />

characteristics of a pulse dampener in higher flow rate<br />

applications. High efficiency mixing yields reproducible<br />

quantitation, better reproducibility of retention times,<br />

and reduced baseline noise due to uniform solvent<br />

composition. Featuring a clean-swept mixing chamber,<br />

the Toroid Mixer has no motors or moving parts.<br />

Toroid Mixer Specifications<br />

Internal Volume: 5mL<br />

Flow Range:<br />

10 to 200mL/min<br />

Maximum Pressure: 6,000psig<br />

Flow Path:<br />

PEEK<br />

TOROID MIXER<br />

DESCRIPTION PART NO. PRICE<br />

Toroid Mixer, Biocompatible 060143<br />

1024<br />

ASI Static Mixer<br />

• Interchangeable mixer cartridges<br />

• Selectable volume*<br />

• Suitable for analytical and micro<br />

<strong>LC</strong> flow rates<br />

ASI HyperShear Static Mixers<br />

use a highly efficient liquid-liquid<br />

shearing interface which induces<br />

vortex mixing over a wide flow rate range. The versatile<br />

cartridge design is available as an in-line, binary, or<br />

ternary inlet housing. Analytical volume housings<br />

accept 350 or 500µL mixer cartridges. Low volume<br />

housings accept 50, 150 or 250µL mixer cartridges. And<br />

Micro volume housings accept 2, 5, 10 or 25µL mixer<br />

cartridges. All are rated to 5000psig.<br />

ASI HYPERSHEAR STATIC MIXERS<br />

DESCRIPTION<br />

SS<br />

PART NO.<br />

PEEK<br />

PART NO.<br />

Analytical Volume Housing<br />

In-Line 40167 —<br />

Binary Inlet 40168 —<br />

Ternary Inlet 40169 —<br />

Analytical Volume Mixer Cartridges<br />

350µL 40146 —<br />

500µL 40147 —<br />

Low Volume Housings<br />

In-line 20141 201411<br />

Binary Inlet 20143 201431<br />

Ternary Inlet 20145 201451<br />

Low Volume Mixer Cartridges<br />

50µL 20147 201471<br />

150µL 20148 201481<br />

250µL 20149 201491<br />

Micro Volume Housing<br />

In-Line 30167 —<br />

Binary Inlet 30168 —<br />

Ternary Inlet 30169 —<br />

Micro Volume Mixer Cartridges<br />

2µL 30146 —<br />

5µL 30147 —<br />

10µL 30148 —<br />

25µL 30166 —<br />

*Other cartridge volumes available, call for assistance.<br />

Contact your Alltech office or distributor for current or local prices.<br />

4707<br />

PRICE<br />

What Should I Consider When<br />

Choosing a Mixer Volume?<br />

• For any given flow rate, the more<br />

mixing volume, the better the<br />

mixing and lower the baseline noise.<br />

• The smaller the mixing volume, the<br />

better the definition and sharpness<br />

of step gradients.<br />

• High pressure multi-pump gradient<br />

systems typically require far less<br />

mixing volume than low pressure<br />

single-pump gradient systems.<br />

257