Warnings<br />

Avoid shock and vibration to the <strong>sensor</strong>.<br />

> Damage to or destruction of the <strong>sensor</strong> and/or the plunger<br />

The oscillator (supply) voltage may not exceed the specified limits (amplitude<br />

and frequency).<br />

>> Damage to or destruction of the <strong>sensor</strong><br />

Protect the <strong>sensor</strong> cable against damage.<br />

>> Destruction of the <strong>sensor</strong><br />

>> Failure of the measuring device<br />

Do not transport the <strong>sensor</strong> on the plunger.<br />

>> Risk of damage to the plunger.<br />

<strong>Assembly</strong> <strong>Instructions</strong><br />

<strong>induSENSOR</strong>, <strong>LVDT</strong> series<br />

Notes on CE Identification<br />

Inductive displacement <strong>sensor</strong>s are not automatically operable devices<br />

(components). An EC declaration of conformity or CE identification is therefore<br />

not required by EMC law 1 . An EMC check of the <strong>sensor</strong>s was done<br />

together with the series MSC 710 signal conditioning electronics.<br />

Proper Environment<br />

-- Protection class:<br />

1<br />

• Displacement <strong>sensor</strong> type TA, SA, LA, SR: IP 40 / IP 67<br />

•Displacement <strong>sensor</strong> type CA, CR: IP 67<br />

-- Operating temperature: -20 °C up to +80 °C<br />

(-4 up to +176 °F)<br />

-- Storage temperature: -40 °C up to +80 °C<br />

(-40 up to +176 °F)<br />

-- Humidity:<br />

5 - 95 % (no condensation)<br />

-- Ambient pressure:<br />

Atmospheric pressure<br />

1) Depends on used mating connector<br />

Installation and <strong>Assembly</strong><br />

Precautions<br />

Do not drop the free moving plunger of an inductive displacement <strong>sensor</strong>.<br />

Protect the cable sheath of the <strong>sensor</strong> cable from sharp edges and pointed<br />

or heavy objects. The minimum bending radius must not be exceeded.<br />

Avoid kinks.<br />

Check the plug connections for firm.<br />

Sensor Mounting<br />

Use peripheral clamping on the <strong>sensor</strong> housing to mount the <strong>sensor</strong>.<br />

This offers the highest reliability because the <strong>sensor</strong> is clamped over a<br />

board area by its cylindrical housing.<br />

Mount the <strong>sensor</strong> using radial point clamping with set screws at<br />

installation locations where there are no forces and vibrations.<br />

Plastic set screws must be used so that the <strong>sensor</strong> housing is not damaged<br />

or deformed.<br />

Screw the plunger of displacement <strong>sensor</strong>s to the measurement<br />

object using the thread.<br />

The screw joint must either be secured with a screw locking compound<br />

(e.g. Loctite ...) or counter-screwed with the lock-nut supplied. When<br />

mounting, it must be ensured that the plunger remains freely movable in<br />

the <strong>sensor</strong> and that tilting is avoided.<br />

Connect the <strong>sensor</strong> to the amplifier electronics by connectors or by<br />

wire terminals depending on the version used (pin assignment).<br />

Ready-made connecting leads are available for <strong>sensor</strong>s with plug connector.<br />

Mounting area<br />

Mounting of displacement <strong>sensor</strong>s<br />

Dimensional Drawings<br />

13<br />

(.51)<br />

Sensor type - CA with integral cable<br />

Dimensions in mm (inches), not to scale<br />

L<br />

Plastic grub screw<br />

Mounting of displacement <strong>sensor</strong>s<br />

with radial point clamping<br />

I<br />

Ø2<br />

(.08 dia.)<br />

10<br />

(.39)<br />

M2<br />

Ø10<br />

(.39 dia.)<br />

9<br />

(.35)<br />

41 (1.61)<br />

30 (1.18)<br />

L<br />

36.5 (1.44)<br />

Female cable<br />

connector C701<br />

Sensor type - SA with axial plug connection<br />

Basic model DTA-1D-- DTA-3D-- DTA-5D-- DTA-10D--<br />

Connection CA SA CA SA CA SA LA CA SA<br />

Length of housing L<br />

Length of plunger l 1<br />

in zero position<br />

Housing diameter<br />

mm<br />

(inches)<br />

mm<br />

(inches)<br />

mm<br />

(inches)<br />

40<br />

(1.57)<br />

19<br />

(0.75)<br />

40<br />

(1.57)<br />

19<br />

(0.75)<br />

57<br />

(2.24)<br />

29<br />

(1.14)<br />

57<br />

(2.24)<br />

29<br />

(1.14)<br />

73<br />

(2.87)<br />

30<br />

(1.18)<br />

10<br />

(0.39)<br />

Housing dimensions for displacement <strong>sensor</strong>s up to ±10 mm measuring range<br />

1) Plunger in zero position / (±10 % of measuring range ±1 mm)<br />

Mounting of displacement <strong>sensor</strong> with peripheral clamping<br />

73<br />

(2.87)<br />

30<br />

(1.18)<br />

78<br />

(3.07)<br />

35<br />

(1.38)<br />

87<br />

(3.43)<br />

35<br />

(1.38)<br />

87<br />

(3.43)<br />

35<br />

(1.38)<br />

Ø2<br />

(.08 dia.)<br />

Ø14<br />

(.55 dia.)<br />

I<br />

10<br />

(.39)<br />

M2<br />

21<br />

(.83)<br />

Ø10<br />

(.39 dia.)<br />

Ø2.7<br />

(.11dia.)<br />

Ø14<br />

(.55 dia.)<br />

26.5<br />

(1.04)<br />

Female cable<br />

connector C701/90


L<br />

I<br />

20 (.79)<br />

Pin Assignment<br />

Sensor type - LA with axial stranded wire<br />

17 (.67) L<br />

Ø4<br />

(.16 dia.)<br />

M4<br />

Ø20<br />

(.79 dia.)<br />

Ø4.8<br />

(.19 dia)<br />

15<br />

(.59)<br />

L<br />

Sensor type - CR with integral (radial) cable<br />

- +<br />

Excitation primary<br />

4<br />

3<br />

1 white<br />

2 black<br />

3 green<br />

4 yellow<br />

5 grey<br />

Type - LA<br />

Stranded wire (axial), length 300 mm<br />

Sensor type - CA with integral cable<br />

9 (.35) L<br />

9.5 (.37)<br />

L<br />

Sensor type - SR with radial plug connection<br />

2<br />

5<br />

1<br />

Signal secondary<br />

Type - CA/CR<br />

Integral cable, length 3 m<br />

1 white<br />

2 brown<br />

3 green<br />

4 yellow<br />

5 grey<br />

Screen<br />

Housing<br />

4<br />

5 1<br />

Typ - SA/SR Housing<br />

Typ - CA/CR<br />

with connector<br />

3<br />

2<br />

Dimensions in mm (inches), not to scale<br />

Sensor type - SA with axial plug connection<br />

Basic model DTA-15D- - DTA-25D- -<br />

Connection LA CA CR SA SR LA CA CR SA SR<br />

Length of housing L<br />

Length of plunger l 1 in<br />

zero position<br />

Housing diameter<br />

mm<br />

(inches)<br />

mm<br />

(inches)<br />

mm<br />

(inches)<br />

92.5<br />

(3.64)<br />

51<br />

(2.01)<br />

106.5<br />

(4.19)<br />

51<br />

(2.01)<br />

106.5<br />

(4.19)<br />

51<br />

(2.01)<br />

Housing dimensions for <strong>sensor</strong>s with ±15 mm measuring range<br />

106.5<br />

(4.19)<br />

51<br />

(2.01)<br />

106.5<br />

(4.19)<br />

51<br />

(2.01)<br />

129.5<br />

(5.10)<br />

62<br />

(2.44)<br />

20 (0.79)<br />

143.5<br />

(5.65)<br />

62<br />

(2.44)<br />

143.5<br />

(5.65)<br />

62<br />

(2.44)<br />

143.5<br />

(5.65)<br />

62<br />

(2.44)<br />

143.5<br />

(5.65)<br />

62<br />

(2.44)<br />

1) Plunger in zero position<br />

(±10 % of measuring range ±1 mm)<br />

Read the detailed instruction manual before using the <strong>sensor</strong>. The manual<br />

is available online on:<br />

www.micro-epsilon.com/download/manuals/man--<strong>induSENSOR</strong>-Serie-<br />

<strong>LVDT</strong>--de-en.pdf<br />

MICRO-EPSILON MESSTECHNIK GmbH<br />

& Co. KG<br />

Königbacher Str. 15 · 94496 Ortenburg<br />

www.micro-epsilon.com<br />

X9771028-A011102HDR<br />

MICRO-EPSILON MESSTECHNIK<br />

*X9771028-A01*