Electrical installation<br />

<strong>Three</strong>−<strong>phase</strong> <strong>AC</strong> motor operation on a frequency inverter<br />

6<br />

Minimum requirements for basic<br />

insulation according to IEC/EN<br />

60664−1 (CE)<br />

3.87 mm<br />

ƒ<br />

ƒ<br />

Higher requirements for UL design<br />

Motor diameter<br />

6.4 mm < 178 mm<br />

9.5 mm > 178 mm<br />

The terminal box has to be free of foreign bodies, dirt, and humidity.<br />

All unused cable entries and the box itself must be sealed against dust and water.<br />

6.2 <strong>Three</strong>−<strong>phase</strong> <strong>AC</strong> motor operation on a frequency inverter<br />

Stop!<br />

Motors MFMA are only suitable for frequency inverter operation.<br />

L−force three−<strong>phase</strong> <strong>AC</strong> motors MMA are suitable for the operation on <strong>Lenze</strong> frequency<br />

inverters and can be combined without restriction.<br />

If another inverter is used for operation, the voltage peaks (U pp ) for given rise times (t R ) as<br />

shown in the diagram must not be exceeded.<br />

Fig. 2<br />

Permissible voltage peaks for frequency inverter operation (characteristic according to IEC<br />

60034−25, curve A)<br />

MT−MDXMA−005.iso/dms<br />

BA 33.0005−EN 2.0<br />

33