8<br />

Maintenance/repair<br />

Important notes<br />

8 Maintenance/repair<br />

8.1 Important notes<br />

Danger!<br />

Hazardous voltage on the power connections even when disconnected from<br />

mains: residual voltage >60 V!<br />

Before working on the power connections, always disconnect the drive<br />

component from the mains and wait until the motor is at standstill.<br />

Verify safe isolation from supply!<br />

Shaft sealing rings and roller bearings have a limited service life.<br />

Regrease bearings with relubricating devices while the lowvoltage machine is running.<br />

Only use the grease recommended by the manufacturer.<br />

If the grease drain holes are sealed with a plug, (IP54 drive end; IP23 drive and nondrive<br />

end), remove plug before commissioning. Seal bore holes with grease.<br />

8.2 Maintenance intervals<br />

Inspections<br />

ƒ If the machine is exposed to dirt, clean the air channels regularly.<br />

8.2.1 Motor<br />

ƒ<br />

ƒ<br />

ƒ<br />

Only the bearings and shaft sealing rings become worn.<br />

– Check bearings for noise (after approx. 15,000 h at the latest).<br />

In order to prevent overheating, remove dirt deposits on the drives regularly.<br />

We recommend carrying out an inspection after the first 50 operating hours. In this<br />

way, you can detect and correct any irregularities or faults at an early stage.<br />

44 <br />

BA 33.0005−EN 2.0