6<br />
Electrical installation<br />
Terminal box HAN connectors<br />
Further information is provided in the system cables system manual at:<br />
www.<strong>Lenze</strong>.com Download Technical documentation Library <br />
X1_Accessories X15_External_accessories X153_System_cables<br />
6.5 Terminal box HAN connectors<br />
Contact pin HAN−Modular 16 A<br />
HAN−GTM−007.iso<br />
HAN−GTM−004.iso<br />
Contact pin HAN−Modular 40 A<br />
HAN−GTM−008.iso<br />
HAN−GTM−004.iso<br />
Terminal box<br />
Module Contact Core colour Connection<br />
a 1 brown Terminal board: U1<br />
2 black Terminal board: V1<br />
3 red Terminal board: W1<br />
b<br />
Blind module<br />
c 1 white or blue Thermal sensor: +KTY / PTC / TCO<br />
2 black Brake + / <br />
3 black Brake − / <br />
4 blue or brown Rectifier: Switching contact<br />
5 blue or brown Rectifier: Switching contact<br />
6 white or black Thermal sensor: −KTY / PTC / TCO<br />
40 <br />
BA 33.0005−EN 2.0