Maintenance/repair<br />
Installation of a spring−applied brake<br />
Readjustment of air gap<br />
8<br />
8.4.3 Readjustment of air gap<br />
Danger!<br />
Disconnect voltage. The brake must be free of residual torque.<br />
9<br />
−<br />
7<br />
10<br />
+<br />
Fig. 5<br />
Air gap adjustment<br />
7 Stator 10 Allen screw<br />
9 Threaded sleeve<br />
KL458−013−a<br />
If "s Lürated " is not within the tolerance, readjust the air gap ( 49).<br />
8.4.4 Assembly of the friction plate, sizes 06 to 16<br />
15<br />
12<br />
Fig. 6<br />
Mounting the friction plate<br />
12 Friction plate 15 End shield<br />
KL458−009−a<br />
1. Put a friction plate (27) or flange (6) against the end shield (15).<br />
Note!<br />
The flanged edge of the friction plate must remain visible!<br />
2. Align pitch circle and fastening bore hole thread.<br />