Electrical installation<br />
Plug connectors<br />
Motor plug connection assignment<br />
6<br />
6.4.1 Motor plug connection assignment<br />
Note!<br />
When making your selection, the motor data and permissible currents of the<br />
cables according to the system cable system manual must be observed.<br />
6.4.2 Power connections<br />
Power / brake / thermal sensor<br />
ICN, 6−pole and 8−pole<br />
6−pole (external view of poles)<br />
Pin Standard description Meaning M23<br />
1<br />
2<br />
BD1 / BA1<br />
BD2 / BA2<br />
Brake + / <br />
Brake − / <br />
PE PE conductor<br />
4<br />
5<br />
6<br />
U<br />
V<br />
W<br />
Power <strong>phase</strong> U<br />
Power <strong>phase</strong> V<br />
Power <strong>phase</strong> W<br />
MT−Steckverbinder−001.iso/dms<br />
8−pole (external view of poles)<br />
Pin Standard description Name M23<br />
1 U Power <strong>phase</strong> U<br />
PE PE conductor<br />
3 W Power <strong>phase</strong> W<br />
4 V Power <strong>phase</strong> V<br />
A<br />
B<br />
TB1 / TP1 / R1<br />
TB2 / TP2 / R2<br />
Thermal sensor TCO /<br />
PTC / + KTY<br />
TCO / PTC / − KTY<br />
C<br />
D<br />
BD1 / BA1<br />
BD2 / BA2<br />
Brake + / <br />
Brake − / <br />
MT−Steckverbinder−001.iso/dms<br />
8−pole (external view of poles) / connection variant ICN 8B<br />
Pin Standard description Name M23<br />
1 U Power <strong>phase</strong> U<br />
PE PE conductor<br />
3 W Power <strong>phase</strong> W<br />
4 V Power <strong>phase</strong> V<br />
A<br />
B<br />
TB1 / TP1 / R1<br />
TB2 / TP2 / R2<br />
Thermal sensor TCO /<br />
PTC / + KTY<br />
TCO / PTC / − KTY<br />
C<br />
D<br />
BD1 / BA 1<br />
BD2 / BA2<br />
Rectifier: Switching<br />
contact<br />
MT−Steckverbinder−001.iso/dms<br />
Connection variant ICN 8B − switching contact of the rectifier for DC switching. Rectifier<br />
supply via motor terminal board. Only possible during mains operation!<br />