8<br />

Maintenance/repair<br />

Maintenance operations<br />

Motor<br />

8.3 Maintenance operations<br />

8.3.1 Motor<br />

Stop!<br />

ƒ Make sure that no foreign bodies can enter the inside of the motor!<br />

ƒ Only work on the drive system when it is in a deenergised state!<br />

ƒ Do not remove plugs when voltage is being applied!<br />

ƒ Hot motor surfaces up to 140 °C. Observe cooling times!<br />

ƒ Remove loads acting on motors or secure loads acting on the drive!<br />

8.3.2 Spring−operated brakes<br />

The brake is mounted to the N−end shield of the motor. Remove the fan cover or blower<br />

unit to check, maintain, or set the brake.<br />

Note!<br />

Brakes with defective armature plates, cheese head screws, springs or counter<br />

friction faces must always be replaced completely.<br />

Generally observe the following for inspections and maintenance works:<br />

ƒ Remove oil and grease linked impurities using brake cleaning agents, if<br />

necessary, replace brake after identifying the cause of the contamination.<br />

Dirt deposits in the air gap between stator and armature plate impair the<br />

function of the brake and must be removed.<br />

ƒ After replacing the rotor, the original braking torque will not be reached<br />

until the run−in operation of the friction surfaces has been completed. After<br />

replacing the rotor, run−in armature plates and counter friction faces have<br />

an increased initial rate of wear.<br />

46 <br />

BA 33.0005−EN 2.0