Maintenance/repair<br />

Maintenance operations<br />

Rotor replacement<br />

8.3.8 Rotor replacement<br />

Danger!<br />

The brake must be free of residual torque.<br />

1. Loosen the connecting cable.<br />

2. Evenly release the screws and remove them completely.<br />

3. Completely remove the stator from the end shield. Observe the connecting cables.<br />

4. Completely remove the rotor from the hub.<br />

5. Check the toothed part of the hub.<br />

6. In case of wear, replace the hub, too.<br />

7. Check the friction surface of the end shield. If the flange / friction plate is severely<br />

gouged, it must be replaced. If the end shield is severely gouged, the friction surface<br />

must be reprocessed.<br />

8. Measure the rotor thickness (new rotor) and the height of head of the sleeve bolts<br />

using a caliper gauge.<br />

9. The distance between the stator and the armature plate is calculated as follows:<br />

Distance = rotor thickness + s Lürated − height of head<br />

"s Lürated ", ( 51)<br />

10. Evenly remove the sleeve bolts until the calculated distance is reached between the<br />

stator and the armature plate.<br />

11. Completely mount the new rotor and set the stator, ( 51).<br />

12. Connect the connecting cable again.<br />

50 <br />

BA 33.0005−EN 2.0