STEAM GENERATOR & FLUID HEATER<br />
INSTALLATION MANUAL<br />
C. Water Treatment Skid All water treatment components are mounted on a skid and<br />
provided along with the steam generator. Components include receiver, softeners, chemical<br />
pumps, blowdown tank, control box, and booster pumps if applicable. Skid piping and electrical<br />
interconnections between the skid components are included.<br />
NOTE<br />
All <strong>Clayton</strong>-supplied water skids must be fully grouted in place once leveling<br />
and anchoring are complete.<br />
D. <strong>Generator</strong> Skid The steam generator(s) and water treatment components as listed in<br />
“C” above, are all mounted on a single skid. Skid piping and electrical interconnections between<br />
components are included.<br />
NOTE<br />
On SCR system skids, the SCR is mounted and piped, but removed for<br />
shipment for reassembly by the installing contractor.<br />
NOTE<br />
<strong>Clayton</strong> reserves the right to ship loose any equipment that cannot be safely<br />
shipped or installed. Some skid components may require re-installation<br />
on site.<br />
NOTE<br />
All <strong>Clayton</strong>-supplied water skids must be fully grouted in place once leveling<br />
and anchoring are complete.<br />
E. <strong>Clayton</strong> Feedwater Pump Skids <strong>Clayton</strong> feedwater pumps are designed to fulfill the<br />
needed water volume and water pressure requirements of the heating unit. These pumps are<br />
mounted on a skid frame that includes all the equipment needed to operate the pump, such as<br />
motors and oil pumps. These feedwater pump skids are standard equipment for all steam generators<br />
and fluid heaters. Piping, piping assemblies, valves, and other plumbing components connecting<br />
the feedwater pump skid and the heating unit are supplied by <strong>Clayton</strong>.<br />
Water supply piping to the feedwater pump skid are the responsibility of the installer, with<br />
the exception of a generator skid. On generator skids, water supply piping to the feedwater pump<br />
skid are part of the generator skid package. For determining the proper water supply pipe sizing,<br />
see Section 2.12.<br />
F. <strong>Clayton</strong>-RotoJet Feedwater Pump Skids Because of the size requirements of this<br />
centrifugal-style feedwater pump, this feedwater pump skid must be installed independent of any<br />
water skid package that <strong>Clayton</strong> offers. For customer connection requirements, see Table 3-1.<br />