2. <strong>Maintenance</strong> Screen<br />

2.2 All Backup Screen<br />

Menus<br />

Menu Details Type Reference<br />

Psswd<br />

input<br />

PLC<br />

stop<br />

All<br />

backup<br />

System<br />

setup<br />

Adjust<br />

S-ana<br />

To<br />

Abs pos<br />

AUX<br />

test<br />

Collect<br />

set<br />

Format<br />

This changes the screen related to the maintenance by setting the<br />

password.<br />

This forcible stops the PLC ladder process. If this menu key is pressed<br />

in the stopped state, the stop is canceled.<br />

This backs up (saves) or restores (reloads) the file such as SRAM etc.<br />

to designated device.<br />

This automatically executes necessary parameter setting for driving<br />

servomotor only by setting necessary minimum item.<br />

This changes the screen to that for adjusting the spindle analog<br />

output.<br />

This sets the absolute position for servo axis (arbitrary NC axis, PLC<br />

axis).<br />

This carries out absolute position setting or test operation by the<br />

auxiliary axis forward run/reverse run.<br />

This menu is only for <strong>70</strong>0 series.<br />

This executes the followings.<br />

Setting to collect the diagnosis data<br />

Confirming the diagnosis data collection status<br />

Starting/Stopping to collect the diagnosis data<br />

Clearing the diagnosis data<br />

This formats the NC memory.<br />

A<br />

C<br />

C<br />

C<br />

C<br />

C<br />

C<br />

C<br />

B<br />

T-life<br />

format<br />

Serial<br />

No.Set<br />

Console<br />

exec<br />

To<br />

In/out<br />

To<br />

param<br />

SRAM<br />

backup<br />

HMI<br />

Quit<br />

This formats the tool life management data.<br />

This changes the NC serial No.<br />

The console is executed. The MS-DOS window will appear.<br />

This changes the screen to the Data Input/Output screen.<br />

This changes the screen to the Parameter screen.<br />

<br />

This backs up the NC SRAM information on the HD.<br />

<br />

This backs up the NC SRAM information on the memory card.<br />

This quits the screen operation.<br />

B<br />

A<br />

C<br />

C<br />

C<br />

B<br />

B<br />

29