2. Maintenanace Screens<br />

2.3 Absolute Position Setting Screen<br />

Initialization start point<br />

a<br />

Basic machine<br />

coordinate system<br />

zero point<br />

Reference<br />

position<br />

c<br />

b<br />

Machine end<br />

stopper<br />

(Mechanical basic<br />

position)<br />

Zero point parameter<br />

"#2037 G53ofs"<br />

#2 Zero-P (#2059 zerbas=1)<br />

#2 Zero-P (#2059 zerbas=0)<br />

Grid point<br />

(electric basic<br />

position)<br />

"Machine end"<br />

(Note 1) To change just the basic machine coordinate zero point, set "#0 Absolute posn set" and "#2 Zero-P",<br />

and then turn the power OFF and ON.<br />

(Note 2) If aligning axis on the marked point is attempted without passing the grip point once after turning the<br />

power ON, the operation message "Not passed on grid" will appear. Return to a point before the last<br />

grid, and then repeat from step of aligning the axis on the marked point.<br />

(Note 3) If the first grid point is covered by the grid mask (#2028 grmask) as a result of return to the electric<br />

basic position, the axis stops at the next grid point.<br />

Note that zero-point shift amount (#2027 G28sft) is invalid.<br />

(Note 4) Reconfirm the "absdir" setting if the machine does not move in the direction of "#2050 absdir". The<br />

machine will move only in the positive direction when set to “0”, and the negative direction when set<br />

to "1".<br />