Broadband Specification Guide<br />

<strong>Functional</strong> <strong>Block</strong> <strong>Diagram</strong><br />

Inserting a Local Origination Above a Cable TV Feed<br />

FROM CATV COMPANY<br />

A<br />

A<br />

(LOW PASS FILTER) ** NOT BY BLONDER TONGUE<br />

- EAGLE COMTRONICS 800-448-7474<br />

http://www.eaglefilters.com<br />

- MICROWAVE FILTER 800-448-1666<br />

http://www.microwavefilter.com<br />

- PCI TECHNOLOGIES 800-565-7488<br />

http://www.pci.com<br />

B<br />

C<br />

#__<br />

G<br />

B<br />

F<br />

(AMPLIFIER)<br />

- RMDA 550-30P # 5500P53<br />

- RMDA 750-30P # 5500P73<br />

- RMDA 860-30P # 5500P83<br />

- RMDA 860-43P # 5500P84<br />

- BIDA 55A-30P # 5800P53<br />

- BIDA 75A-30P # 5800P73<br />

- BIDA 86A-30P # 5800P83<br />

- BIDA 55A-43P # 5800P54<br />

- BIDA 75A-43P # 5800P74<br />

- BIDA 86A-43P # 5800P84<br />

- BIDA 100A-30 # 5800-13<br />

E<br />

D<br />

C<br />

(MODULATOR)<br />

- AM-60-860 /OPT. 5 # 59415A / 5905 (AGILE 860 MHz STEREO)<br />

- MAVM-861 # 7992B (FIXED CHANNEL)<br />

**THE FOLLOWING MUST BE USED WITH “G”<br />

- MICM-45C #7797C (MODULAR FIXED CHANNEL)<br />

- MICM-45S #7797S (MODULAR FIXED CHANNEL - STEREO)<br />

- AMM-806 #7763 (MODULAR - AGILE)<br />

- AMCM-860 #7766B (MODULAR-AGILE)<br />

F<br />

D<br />

(COMBINER)<br />

- OC-8D COMBINER # 5957<br />

- OC-12D COMBINER # 5953<br />

- OC-24E COMBINER # 5794<br />

- OC-32E COMBINER # 5795<br />

E<br />

(COMBINER - ALL CHANNELS GET COMBINED AT SAME LEVEL)<br />

- SXRS-2 # 1922 (COMBINES BOTH INPUTS WITH SAME LEVELS)<br />

- SRT-** 1940-** (CATV FEED AND LOCAL SOURCE ARE DIFFERENT<br />

LEVELS; TAP VALUE IS DIFFERENCE AND TAP PORT CONNECTS<br />

TO HIGHER LEVEL SOURCE)<br />

G<br />

(MODULAR RACK CHASSIS & POWER SUPPLY)<br />

- MIRC-4D # 7711 (4 SLOT CHASSIS & POWER SUPPLY)<br />

- MIRC-12V # 7715 (12 SLOT CHASSIS)<br />

- MIPS-12C # 7722C (12 UNIT POWER SUPPLY)<br />

BLONDER TONGUE LABORATORIES INC.<br />

OLD BRIDGE, NEW JERSEY 08857<br />

DRAWN<br />

ENGINEER<br />

07/31/06 WNW<br />

DWG NO.<br />

AC-021405I<br />