Broadband Specification Guide<br />

Equipment Specifications Library<br />

SXRS-4<br />

The indoor, four-way splitter shall be constructed in a die-cast housing with a soldered back plate to ensure high RFI shielding. The splitter should have an<br />

in-line connector orientation, and the connectors on the unit shall be type F. The RFI shielding shall be at least 120 dB to prevent signal ingress or egress.<br />

The indoor, four-way splitter shall be equal to <strong>Blonder</strong> <strong>Tongue</strong> SXRS-4 and shall meet or exceed the following specifications:<br />

a) Frequency Range: 5 to 1000 MHz<br />

b) Isolation: 25 dB Minimum<br />

c) Return Loss: 18 dB Minimum<br />

d) Insertion Loss: 8 dB Maximum<br />

e) RFI Shielding: 120 dB Minimum<br />

SXRS-8<br />

The indoor, eight-way splitter shall be constructed in a die-cast housing with a soldered back plate to ensure high RFI shielding. The splitter should have an ‘L-style’<br />

connector orientation, and the connectors on the unit shall be type F. The RFI shielding shall be at least 120 dB to prevent signal ingress or egress. The indoor, eightway<br />

splitter shall be equal to <strong>Blonder</strong> <strong>Tongue</strong> SXRS-8 and shall meet or exceed the following specifications:<br />

a) Frequency Range: 5 to 1000 MHz<br />

b) Isolation: 22 dB Minimum<br />

c) Return Loss: 15 dB Minimum<br />

d) Insertion Loss: 12 dB Maximum<br />

e) RFI Shielding: 120 dB Minimum<br />

TF-GF-FT<br />

The wall plate shall be designed to fit all standard single-gang electrical boxes. It shall have a “G/F” style feed thru connector mounted in the center of a steel cover<br />

plate. The cover plate shall be painted a textured ivory. The wall plate shall have high RFI shielding characteristics for CATV applications. The wall plate shall be equal<br />

to <strong>Blonder</strong> <strong>Tongue</strong> TF-GF-FT.<br />

TVCB-PC<br />

The TV channel blocker shall provide 40 channel blocking capability from channel 2 to 86 (54-600 MHz) with a passband up to 860 MHz. The blocker shall have push<br />

button controls and an LED display for setting the channels to be blocked. The blocker’s enclosure shall provide tamper protection on the RF connections and have<br />

provisions for locking to prevent unauthorized access. The channel blocker shall be equal to <strong>Blonder</strong> <strong>Tongue</strong> TVCB-PC and shall meet or exceed the following specifications.<br />

a) Bandwidth: 54 to 860 MHz<br />

b) Nominal Gain: 1.5 dB<br />

c) Flatness: ±1.5 dB<br />

d) Return Loss: 16 dB<br />

e) Output Level (when input is 9 dBmV @54 MHz;<br />

15 dBmV @ 600 MHz):<br />

(1) 54 MHz: 10 dBmV<br />

(2) 600 MHz: 16 dBmV<br />

(3) 750 MHz: 17 dBmV<br />

(4) 860 MHz: 18 dBmV<br />

f) Distortions (@ 77 Channel Loading):<br />

(1) CTB: -60 dBc<br />

(2) CSO: -60 dBc<br />

(3) Spurious: -60 dBc<br />

(4) C/N: 59 dB<br />

V-1GF-FT<br />

g) Return Path Bandwidth: 5 to 40 MHz<br />

h) Return Path Gain: - 2 dB<br />

i) Number of Jamming<br />

Oscillators: 8 (54 - 600 MHz )<br />

j) RF Leakage: Complies with FCC Part 76, Sub part K<br />

k) Power Requirements Voltage: 37-95 VAC<br />

l) Current Consumption @ 60 VAC IN: 200 mA<br />

m) Operating Temperature<br />

Range: -40° to +60° C<br />

n) Relative Humidity: 5-100 %<br />

o) Housing - Dimensions:<br />

9.5 x 4.0 x 10.0 in., (L x H x W)<br />

p) Connectors: “F” Type, Female<br />

The wall plate shall be designed to fit all standard electrical boxes. It shall have a “G/F” feed thru connector mounted on a steel back plate for mechanical<br />

strength. The wall plate shall have a duplex style plastic ivory filler plate and requires a standard duplex cover plate to finish it off. The wall plate shall have<br />

high RFI shielding characteristics for CATV applications. The wall plate shall be equal to <strong>Blonder</strong> <strong>Tongue</strong> V-1GF-FT.<br />