Broadband Specification Guide<br />
Equipment Specifications Library<br />
RMDA-750-30P<br />
The headend launch amplifiers shall be housed in an industry standard 19” EIA rack mountable enclosure. The amplifiers shall employ power doubling hybrid circuitry<br />
for forward path amplification and be UL listed. The amplifiers shall be equal to <strong>Blonder</strong> <strong>Tongue</strong> RMDA-750-30P, and shall meet or exceed the following specifications:<br />
a) Forward Passband: 47 to 750 MHz<br />
b) Flatness: ±1.00 dB<br />
c) Gain: 31 dB<br />
d) Manual Gain Control Range: 15 dB<br />
e) Manual Slope Control Range: 10 dB<br />
f) Test Ports:<br />
(1) Input: -20 ±2 dB<br />
(2) Output: -20 ±2 dB<br />
g) Return Loss:<br />
(1) Input: 14 dB Minimum<br />
(2) Output: 14 dB Minimum<br />
h) Impedance: 75 Ω<br />
RMDA-860-30P<br />
The headend launch amplifiers shall be housed in an industry standard 19” EIA rack mountable enclosure. The amplifiers shall employ power doubling hybrid circuitry<br />
for forward path amplification and be UL listed. The amplifiers shall be equal to <strong>Blonder</strong> <strong>Tongue</strong> RMDA-860-30P, and shall meet or exceed the following specifications:<br />
a) Forward Passband: 47 to 860 MHz<br />
b) Flatness: ±1.00 dB<br />
c) Gain: 31 dB<br />
d) Manual Gain Control Range: 15 dB<br />
e) Manual Slope Control Range: 10 dB<br />
f) Test Ports:<br />
(1) Input: -20 ±2 dB<br />
(2) Output: -20 ±2 dB<br />
g) Return Loss:<br />
(1) Input: 14 dB Minimum<br />
(2) Output: 14 dB Minimum<br />
h) Impedance: 75 Ω<br />
RMDA-860-43P<br />
The headend launch amplifiers shall be housed in an industry standard 19” EIA rack mountable enclosure. The amplifiers shall employ power doubling hybrid circuitry<br />
for forward path amplification and be UL listed. The amplifiers shall be equal to <strong>Blonder</strong> <strong>Tongue</strong> RMDA-860-43P, and shall meet or exceed the following specifications:<br />
a) Forward Passband: 47 to 860 MHz<br />
b) Flatness: ±1.00 dB<br />
c) Gain: 43 dB<br />
d) Manual Gain Control Range: 15 dB<br />
e) Manual Slope Control Range: 10 dB<br />
RMDA-86A-30<br />
i) Noise Figure: 7.0 dB Maximum<br />
j) Hum Modulation: -70 dB<br />
k) Number of Channels: 110<br />
l) Output Level:<br />
(1) Lowest Channel: 36 dBmV<br />
(2) Highest Channel: 44 dBmV<br />
m) Composite Triple Beat Distortion -66 dB<br />
n) Cross Modulation: -67 dB<br />
o) Transformer AC input: 120 VAC, 60 Hz<br />
p) Operating Temperature: -20° C to 60° C<br />
i) Noise Figure: 8.5 dB Maximum<br />
j) Hum Modulation: -70 dB<br />
k) Number of Channels: 129<br />
l) Output Level:<br />
(1) Lowest Channel: 36 dBmV<br />
(2) Highest Channel: 44 dBmV<br />
m) Composite Triple Beat Distortion: -61 dB<br />
n) Cross Modulation: -59 dB<br />
o) Transformer AC input: 120 VAC, 60 Hz<br />
p) Operating Temperature: -20° C to 60° C<br />
The distribution amplifiers shall be housed in an industry standard 19” EIA rack mountable enclosure. The amplifiers shall employ push pull hybrid circuitry for both<br />
forward and return path amplification. The amplifier shall be field selectable for either active or passive reverse path operation. The amplifier shall have optional<br />
plug-in equalizer and attenuator capability for input signal conditioning. The unit shall be powered via an external UL listed 26 VAC power supply. The amplifiers shall<br />
be equal to <strong>Blonder</strong> <strong>Tongue</strong> RMDA-86A-30, and shall meet or exceed the following specifications:<br />
a) Forward Passband: 54 to 860 MHz<br />
b) Return Passband: 5 to 40 MHz<br />
c) Flatness: ±1.00 dB (Fwd), ±0.5 dB (Rev)<br />
d) Gain: 32 dB (Fwd), 22 dB (Rev)<br />
e) Manual Gain Control Range:<br />
10 dB (Fwd), 18 dB (Rev)<br />
f) Manual Slope Control Range: 8 dB (Fwd)<br />
g) Impedance: 75 Ω<br />
h) Noise Figure: 8.5 dB Maximum (Fwd), 6.0 dB (Rev)<br />
f) Test Ports:<br />
(1) Input: -20 ±2 dB<br />
(2) Output: -20 ±2 dB<br />
g) Return Loss:<br />
(1) Input: 14 dB Minimum<br />
(2) Output: 14 dB Minimum<br />
i) Hum Modulation: -70 dB<br />
j) Number of Channels (Fwd): 129<br />
k) Output Level (Fwd):<br />
(1) Lowest Channel: 34 dBmV<br />
(2) Highest Channel: 42 dBmV<br />
l) Composite Triple Beat Distortion: -58 dB<br />
m) Cross Modulation: -58 dB<br />
n) Transformer AC input: 120 VAC, 60 Hz<br />
o) Operating Temperature: -20° C to 60° C<br />