CHEMICAL RESISTANCECLEAR - ECO-MPE 1 Day 7 DaysAcids, Inorganic10% Hydrochloric Acid E E30% Hydrochloric Acid (Muriatic) E G10% Nitric Acid E G50% Phosphoric Acid F F37% Sulfuric Acid (Battery Acid) G GAcids, Organic10% Acetic Acid G F10% Citric Acid G GOleic Acid G FAlkalies10% Amm<strong>on</strong>ium Hydroxide E E50% Sodium Hydroxide E ESolvents (Alcohols)Ethylene Glycol (Antifreeze) E GIsopropyl Alcohol F PMethanol F FSolvents (Aliphatic)d-Lim<strong>on</strong>ene G GJet Fuel - JP-4 E EGasoline G GMineral Spirits E ESolvents (Aromatic)Xylene F FSolvents (Chlorinated)Methylene Chloride P PSolvents (Ket<strong>on</strong>es & Esters)Methyl Ethyl Ket<strong>on</strong>e (MEK) P PPropylene Glycol Methyl Ether Acetate(PMA)F FMiscellaneous Chemicals20% Amm<strong>on</strong>ium Nitrate E EBrake Fluid F FBleach E EMotor Oil (SAE 30) E ESkydrol® 500B F FSkydrol® LD4 F F20% Sodium Chloride E E1% Tide® Laundry Soap E E10% Trisodium Phosphate E EBased <strong>on</strong> 1-day and 7-day spot testing <strong>on</strong> c<strong>on</strong>crete.<str<strong>on</strong>g>Coating</str<strong>on</strong>g> cured 2 weeks prior to testing.Legend:E - Excellent (No Adverse Effect) - Recommended.G - Good (Limited Adverse Effect--such as softening or staining) -Use for short-term exposure <strong>on</strong>ly.F - Fair (Moderate Adverse Effect) - Not recommended.P - Poor (Unsatisfactory) - Little or no resistance to chemical.Note:Reduced chemical resistance and increased staining ispossible in pigmented versi<strong>on</strong>s of this system.Tide ® is a registered trademark of Proctor and Gamble.Skydrol ® is a registered trademark of M<strong>on</strong>santo.TORFP GJKZ 09-0063 <str<strong>on</strong>g>SOW</str<strong>on</strong>g> <str<strong>on</strong>g>Attachment</str<strong>on</strong>g> DAppendix D Existing <str<strong>on</strong>g>Epoxy</str<strong>on</strong>g> <str<strong>on</strong>g>Coating</str<strong>on</strong>g> <str<strong>on</strong>g>System</str<strong>on</strong>g> DataIMPORTANT:READ AND FOLLOW ALL PRECAUTIONS ANDINSTRUCTIONS BEFORE PROCEEDING.PRELIMINARY FLOOR INSPECTIONSCHECK THE CONCRETE: C<strong>on</strong>crete must be structurallysound and free of curing membrane, paint or other sealer. Ifyou suspect that the c<strong>on</strong>crete has been previously sealed,call Tennant Company, technical support for furtherinstructi<strong>on</strong>s.CHECK FOR MOISTURE: C<strong>on</strong>crete must be dry beforeapplicati<strong>on</strong> of this floor coating material. C<strong>on</strong>crete moisturetesting must occur. Calcium chloride testing or in-situ relativehumidity testing is recommended. Readings must be below3 pounds per 1,000 square feet (1.5 kg per 150m 2 ) over a24-hour period <strong>on</strong> the calcium chloride test or below 75%relative internal c<strong>on</strong>crete humidity. Test methods can bepurchased at www.astm.org, see ASTM F1869 or F2170,respectively or follow instructi<strong>on</strong>s from the suppliers of thesetests.NOTE: Although testing is critical, it is not a guaranteeagainst future problems. This is especially true if there is novapor barrier or the vapor barrier is not functi<strong>on</strong>ing properlyand/or you suspect you may have c<strong>on</strong>crete c<strong>on</strong>taminati<strong>on</strong>from oils, chemical spills or excessive salts.CHECK THE TEMPERATURE AND HUMIDITY: <strong>Floor</strong>temperature and materials should be between 65°F (18°C)and 90°F (32°C). Humidity must be less than 80%. DO NOTcoat unless floor temperature is more than five degrees overthe dew point.APPLICATION EQUIPMENT• Protective clothing• Jiffy ® Mixer Blade[Tennant Part No. 08643-1 (small unit) or08643-5 (large unit)]• Slow speed drill (500 rpm or less)• 18-24" (46-61 cm) Flat rubber squeegee• 18-24" (46-61 cm) Notched rubber squeegee• Roller Assembly• Shed Resistant, 3/8" (10 mm) Nap Rollers• Spiked shoes• 60 grit sandpaper [Tennant Part No. 65449]• 80 grit sandpaper [Tennant Part No. 65450]• 100 grit sandpaper [Tennant Part No. 65451]ASSEMBLE EQUIPMENT: Due to the limited pot life of thematerial, all applicati<strong>on</strong> equipment, etc. should be ready forimmediate use. (Clean roller with tape to remove anyresidual lint.)PREPARATIONDetergent scrub and rinse with clean water to removesurface dirt, grease, oil and c<strong>on</strong>taminants.THIN FILM APPLICATIONS (3-10 mils / 76.2-254 micr<strong>on</strong>s):Acid Etch (bare c<strong>on</strong>crete): Detergent scrub and rinse withclean water.Tennant Eco-Prep or Diam<strong>on</strong>d Grind: Scrub with TennantAcid Wash and rinse with clean water (results of diam<strong>on</strong>dgrinding may vary depending <strong>on</strong> technique and the hardnessof the c<strong>on</strong>crete. Additi<strong>on</strong>al mils may be required).Eco-MPE © Tennant Company 02/09/09 Page 2 of 447 of 57

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!