REPROTOADDRESS(address)specifies the relative byte address (RBA) of the last record you wantcopied. Unlike FROMADDRESS, the RBA value does not need to be thebeginning of a logical record. The entire record containing the specifiedRBA is copied.If you specify this parameter <strong>for</strong> a KSDS, the records are copied in physicalsequential order instead of in logical sequential order.Use TOADDRESS with VSAM key-sequenced or entry-sequenced data setsor components. TOADDRESS cannot be specified when the data set isaccessed through a path. TOADDRESS cannot be specified <strong>for</strong> akey-sequenced data set with spanned records if any of those spannedrecords are to be accessed.addresscan be specified in decimal (n) or hexadecimal (X'n'). The specificationcannot be longer than one fullword.The largest address you can specify in decimal is 4,294,967,295. If yourequire a higher value, specify it in hexadecimal.Abbreviation: TADDRTONUMBER(number)specifies the relative record number of the last record you want copied.TONUMBER can be specified only when you copy a relative recorddata set.numberCan be specified in decimal (n), hexadecimal (X'n'), or binary (B'n').The specification cannot be longer than one fullword.The largest address you can specify in decimal is 4,294,967,295. If yourequire a higher value, specify it in hexadecimal.Abbreviation: TNUMCOUNT(number)specifies the number of logical records you want copied. COUNT shouldnot be specified when you access the data set through a path; results areunpredictable.VOLUMEENTRIES(entryname)specifies the tape volume catalogs to be merged or copied. The LEVELparameter is not allowed when merging tape volume catalogs. When atape volume catalog is copied, REPRO verifies that the target is a tapevolume catalog.Abbreviation: VOLENTRIES or VOLENTCryptographic ParametersYou can use the REPRO cryptographic parameters with the following facilities:vvIBM Programmed Cryptographic Facility (PCF) (5740-XY5)Change your configuration to use the cryptographic parameters with PCF.z/<strong>OS</strong> Integrated Cryptographic Service Facility (ICSF) (5647-A01)Change your ICSF configuration to use the cryptographic parameters with ICSF.For a description of the necessary changes, see z/<strong>OS</strong> Cryptographic <strong>Services</strong> ICSFSystem Programmer’s Guide.314 z/<strong>OS</strong> <strong>V1R6.0</strong> <strong>DFSMS</strong> <strong>Access</strong> <strong>Method</strong> <strong>Services</strong> <strong>for</strong> <strong>Catalogs</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!