10.07.2015 Views

IQ plus® 800/810 - Rice Lake Weighing Systems

IQ plus® 800/810 - Rice Lake Weighing Systems

IQ plus® 800/810 - Rice Lake Weighing Systems

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

SETPOINTCLEARLbKgROCAccumScale 1SETPOINTPress to show defined setpoint values. When you first press this key, the display shows SP 1 fortwo seconds, then switches to show the setpoint value. Each time you press SETPOINT, thenext defined setpoint is shown.You can change the setpoint value by keying in a number and pressing ENTER. To turn off asetpoint, press CLEAR. The message OFF appears on the display for disabled setpoints.NOTE: In Version 3.1, you can reactivate setpoints that have been turned off at the front panel.Press the SETPOINT key to show the OFF status for the setpoint, then press ENTER to turn thesetpoint back on.If you make an error when keying in a value, press CLEAR to erase individual digits. To returnto normal mode, press G/N or wait for the display to switch back.You can use the SETPOINT key to view or change preact values from the front panel during thenormal mode. See Section 8.3 on page 62 for more information using the SETPOINT key toaccess preact values.See Section 8.4 on page 62 for more information about naming setpoints.CLEARErases digits entered from the keyboard or clears special function values.• In the SETPOINT function, CLEAR disables setpoints or erases individual digits.• In the DISP ACCUM function, with the current accumulator value displayed, press CLEARto display the prompt CLR ACn (where n is the accumulator number, 0–4). Press CLEAR asecond time to clear the accumulator.• In the DISP TARE function with the current tare value displayed, press CLEAR to displaythe prompt CLR TR?. Press CLEAR a second time to clear the tare register.• In the DISP TARE function (truck in/out mode), CLEAR erases truck IDs, as well as tarevalues.LED AnnunciatorsThe LED annunciators provide status information about the indicator.The LEDs on the left side of the display indicate the display units and whether the valuedisplayed is a rate of change or accumulator value. The Lb and Kg (Units) LEDs function asfollows:• If the displayed weight is in pounds, the Lb LED is lit; if kilograms, the Kg LED is lit.• If the primary unit of weight is pounds, the Kg LED is lit for secondary units—or, if theprimary unit is kilograms, the Lb LED is lit for secondary units, unless the secondary unitof weight is the same as the primary unit.• If neither primary nor secondary units are pounds or kilograms, the Lb LED is used as aprimary units annunciator and the Kg LED is used as the secondary units annunciator.See the descriptions of the UNITS, DISP ROC, and DISP ACCUM keys for more information.The scale channel LEDs on the right side of the display indicate which scale weight isdisplayed. See the description of the SCALE # key for more information.Scale 2Scale 3Scale 4Introduction 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!