10.07.2015 Views

IQ plus® 800/810 - Rice Lake Weighing Systems

IQ plus® 800/810 - Rice Lake Weighing Systems

IQ plus® 800/810 - Rice Lake Weighing Systems

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CONFIG MenuParameter Choices DescriptionFEATUREACCUMROCPEAKPASSWRDA/BAllows you to verify current feature status or to activate a feature. See the Level 3parameter descriptions on page 18 for information about activating these features.DEFAULT RESET Press the down (TIME/DATE) key to reset configuration parameters to default values. Thisparameter is available only with software versions 3.13 and later.NOTE: Indicator must be reconfigured and load cells recalibrated after performing thisfunction.Level 3 submenusGRADS number Graduations. Specifies the number of full scale graduations. The value entered should beconsistent with legal requirements and environmental limits on system resolution. Enter avalue with the numeric keypad; exit upward to save the new value.ZTRKBND OFF0.5 D1 D3 DZRANGE 1.9%100%MOTBAND 1D2 D3 D5 D10 D20 DOFFOVRLOAD FS + 2%FS + 1DFS + 9DFSTo calculate GRADS, use the formula, GRADS = Capacity / Display Divisions.Display divisions for primary and secondary units are specified on the FORMAT menu.Zero track band. Automatically zeroes the scale when within the range specified, as longas the input is within the ZRANGE and scale is at standstill. Selections are ± displaydivisions. Maximum legal value varies depending on local regulations.Zero range. Selects the range within which the scale can be zeroed. The 1.9% selection is± 1.9% around the calibrated zero point, for a total range of 3.8%. Indicator must be instandstill and in gross weight display mode to zero the scale. Use 1.9% for legal-for-tradeapplicationsWhen the ZERO key is pressed while displaying the total channel, the amount on eachindividual channel is zeroed off, if possible. If the ZERO is not possible on all channels,then the ZERO is denied.Motion band. Sets the level, in display divisions, at which scale motion is detected bycomparing the current display with the previous display. If motion is not detected for 1second or more, the standstill symbol lights, enabling the scale to process a PRINTcommand. Maximum legal value varies depending on local regulations.If OFF is selected, ZTRKBAND must also be set to OFF. TOTAL channel is considered atstandstill when all individual channels are out of motion.Overload. Determines the point at which the display blanks and an out-of-range errormessage is displayed. Maximum legal value varies depending on local regulations.When any individual channel is overloaded, the total channel display is also blanked.Table 3-2. Configuration Menu Parameters (Continued)Configuration 17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!