10.07.2015 Views

Biennial Report 2005-2007 - Saha Institute of Nuclear Physics

Biennial Report 2005-2007 - Saha Institute of Nuclear Physics

Biennial Report 2005-2007 - Saha Institute of Nuclear Physics

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

High Energy <strong>Physics</strong> and Microelectronics 87Fig.3.1.1.1The MANAS has 16 channels and 1,08,000 chips were delivered in 4 gain-bins with ∼2% gain-spreadin each bin and all the 1.7 million channels have a pedestal dispersion <strong>of</strong> only 160 mV. These wereensured by thorough testing at SINP and careful analysis <strong>of</strong> the test-data <strong>of</strong> UTAC.Md Danish Azmi†, Suvendu Nath Bose, Sukalyan Chattopadhyay, Dipankar Das, Indranil Das,Pradip Datta†, Md Irfan, Shampa Jana, Sanjoy Pal, Lipy Paul, Pradip Roy, Tinku Sinha HEP3.1.1.2 Production <strong>of</strong> 10 Muon ChambersThis was the first large scale in-house detector production at SINP. These detectors are the largestCathode Pad Chambers and the magnitude <strong>of</strong> the job can be estimated by fact that•Total <strong>of</strong> ∼7,75,000 solder points were necessary for the readout and associated electronics

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!