DELTABOOSTER_GB01<br />

Trouble-shooting<br />

Red light turns on - machine does not start up<br />

Symptom Reason Check<br />

Temperature in tank > 80°C Disconnect plug X8 from circuit board A1<br />

Temperature sensor B7 defective/<br />

short-circuited/ interrupted 7<br />

8 Ω<br />

See technical data, page A7<br />

Level switch in B6 or connection Disconnect plug X7 from circuit board<br />

defective/interrupted/sticks. In case of a full<br />

11 tank, B6 must<br />

12 Ω be connected.<br />

See page C1<br />

Level switch B8 or connection Disconnect plug X8 from circuit board<br />

defective/short-circuited/blocked/placed In case of a full<br />

wrongly. 09 tank, B8 must<br />

10 Ω be disconnected.<br />

See page C1<br />

Overflow switch B4 or connection Disconnect plug X7 from circuit board.<br />

defective/short-circuited/stuck. OK if connection<br />

7 broken off.<br />

8 Ω<br />

Overflow switch - see page E11<br />

D<br />

Pressure switch (HP) B1 or supply Disconnect plug X7 from circuit board.<br />

lines short-circuited/stuck. In pressure-relieved<br />

1 condition, broken<br />

2 Ω connection must<br />

appear.<br />

Pressure switch - see page E13<br />

Motor protection Q1 disconnected. Adjustment according to model tag.<br />

Voltage too low. Motor short-circuited. Measurement of insulations<br />

Motor missing phase. and winding resistance<br />

Motor protection adjusted too low.<br />

Water leakage<br />

See page F4<br />

Starting-up Problems<br />