Trouble-shooting<br />

The reason why the pump pressure is too low may have been one of the following:<br />

1. The number of nozzles in use exceeds the pump capacity, or the nozzles used may be worn.<br />

2. Pipeline narrowed due to scale or dirt.<br />

3. Pre-nozzle of multipressure spray lance clogged up.<br />

4. Pipeline leaky.<br />

5. A pump does not run.<br />

6. Safety valve V2 of pump adjusted too low or defective.<br />

7. Overflow valve V1 adjusted too low, worn or clogged up.<br />

8. Suction and/or pressure valves worn or clogged up.<br />

9. Pressure sleeves worn.<br />

10. Air in the pump.<br />

For the encirclement of the fault reason, the following diagram can be used.<br />

D<br />

Pump Pressure Low<br />

The plant is a 160 bar plant. In the case of a 120 bar plant, proportionally lower values apply.<br />