Fault in the electrical control system<br />

DELTABOOSTER_GB01<br />

Trouble-shooting<br />

D<br />

Printed Circuit Coard<br />

Interruptions of operation where the fault cannot be assigned to the previous pages 1 to 9 may be<br />

due to faults in the electrical control system, the circuit board.<br />

The printed circuit board is protected against an overloading by means of a fuse F4, which has<br />

been placed on the P.C. board. If this fuse blows more than once, the P.C. board must be considered<br />

to be defective.<br />

For protection of the outlet X4 to motor relays, X5 for the softener pump + relief valve and X6 for<br />

the solenoid valves, hot and cold, fuse F3 has been placed on the secondary side of the transformer<br />

in the upper part of EPM. If this fuse blows too, when the plugs X4-X5-X6 are dismounted,<br />

the P.C. board must be considered to be defective. If not, check various connections.<br />

See section F page 4.<br />