Suction side<br />

DELTABOOSTER_GB01<br />

<strong>Service</strong> / <strong>Repair</strong><br />

Pressure side<br />

E<br />

Safety Valve<br />

At the factory the safety valve has been set at opening pressure = working pressure + 50 bar.<br />

When checking-up the machine the adjustment should be checked and maybe adjusted.<br />

When mounting, use grease to make the ball and the thrust plate stick to the spring.<br />

The seat is screwed on by a 10 mm box spanner (no gasket required).<br />

Before testing with a pressure gauge, you should make sure that 2 threads are visible behind<br />

the lock nut.<br />

Disconnect the other motors on the motor protection.<br />

NOTE: Before starting up the pump, ensure that the valve of the test pressure gauge is open.<br />

Slowly close the valve. Never exceed 250 bar.<br />

10 mm special key no:1206754<br />

6 mm hexagon<br />

box wrench<br />

Adaptor<br />

no:1220126<br />

Test pressure gauge<br />

no:1206358<br />

Test tube no: 1211994<br />