(2) Trigger● Insert each meter pen to each trigger outgoing line to measure trigger resistance.Trigger headresistance80~130ΩC. AdjustmentAdjust the clearance between the trigger head and rotor.Trigger headclearance.020-.029 in. (0.50~0.75 mm)Insert the feeler gauge between the bulge on the trigger head and the rotor to measure clearance.Loosen the two bolts on the bracket to obtain the proper. When tightening, apply equal torque to bothmounting bolts to prevent “cocking” the trigger to one side. Recheck the clearance after the adjustmenthas been made.38