11.07.2015 Views

T Catalogue 2010 - Tridonic

T Catalogue 2010 - Tridonic

T Catalogue 2010 - Tridonic

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

U – LED modules, converters and systemsumoduleUstrip ES 08/10/12ustrip, EmergencyProduct description• Lighting module with 8, 10 or 12 high-power LEDs(emergency lighting strip)• For use in escape route signsProperties• Suitable for <strong>Tridonic</strong> EM powerLED emergency lighting units• For permanent and standby operation• Wide 120° distribution of light for uniform illumination• Operation on a constant current source• Replacement for 8 W T5 flourescent lamp• Several options for uniform light distribution• Can be interconnected to create longer strips• Low energy consumptionposition to attach leadsat each end of pcb15,8• Long life thanks to low operating temperature• Provides a maintenance-free escape sign system• Polarity reversal protection for batteryDLD• Simple mounting/installationNoteSeparate status LED required (page 83 and page 86)ÊÊFor product data sheet go to www.tridonic.com,or available on requestÈProduct matrix, page 23Standards, page 23Colour temperatures and tolerances, page 132Ordering dataColourColourtemperatureTypeArticle number8 light points per moduleDaylight white 6,500 K ES 08 246 89899954Daylight white 6,500 K ES 08 285 8989994710 light points per moduleDaylight white 6,500 K ES 10 285 8989994812 light points per moduleDaylight white 6,500 K ES 12 285 89899949Packaging: 25 pieces/carton, 600 pieces/palletSpecific technical dataType Typ. luminous flux 13 Max. current 2 Power 13 Ambient temperature ta 3 tc point4 Total length Hole spacing D8 light points per moduleES 08 246 60 lm 350 mA typ. 1.1 W -20 ... +40 °C 60 °C 246 mm 97.9 mmES 08 285 60 lm 350 mA typ. 1.1 W -20 ... +40 °C 60 °C 285 mm 106.8 mm10 light points per moduleES 10 285 60 lm 350 mA typ. 1.1 W -20 ... +40 °C 60 °C 285 mm 106.8 mm12 light points per moduleES 12 285 60 lm 350 mA typ. 1.1 W -20 ... +40 °C 60 °C 285 mm 106.8 mm1 Tolerance range for optical and electrical data: ±15 %2 Exceeding the max. operating current leads to an overload on the ustrip. This may in turn result in a significant reduction in lifetime or even destruction of the ustrip.3 Data for operation with 350 mA4 If the max. temperature limits are exceeded, the life of the module will be reduced or the module may be damaged. The temperatureof the ustrip at the tc-point is to be measured in the thermally stable state. For tc-point see the above diagram.All values at ta = 25 °C.T <strong>Catalogue</strong> <strong>2010</strong>www.tridonic.com 81

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!