CLEARANCESMinimum Wall and Ceiling ClearancesMantel Clearances for Built-in Installation36”(91.44 cm)2” (5.08 cm)MANTEL12”(30.5cm)10”11”(25.4cm)(27.9cm)8”10 1/4”(20.3cm)(26.0cm)6”9½”(15.2cm)(24.1cm)8 3/4”(22.2cm)5½”(14.0cm)4 3/4”(12.1cm)TOP OF FRAME 04”(10.2cm)2½”(63.0cm)COMBUSTIBLESALLOWEDFigure 8This fireplace can be installed with zero (0") clearance tocombustible material.When facing the front of the appliance the minimum clearances tocombustible construction (material) are the following:1. Clearances from the right side or left side of the fireplace openingto any combustible wall or material should not be less than 2inches.2. Clearances from the top of the fireplace opening to the ceilingshould not be less than 36 inches.Figure 9COMBUSTIBLE MATERIALDo not attach combustible material to the mantel of your fireplace.This is a fire hazard.No greeting cards, stockings or ornamentation of any type should beplaced on or attached to the fireplace. This is a heating appliance.The flow of heat can ignite combustibles.HEATFLOWFigure 10Figure 11Page 1230816-1-0912