TABLE 12MAXIMUM VENT PIPE LENGTHS DIRECT VENT (2 PIPE)ALTITUDEG43UFMODEL 2"dia.MAXIMUM EQUIVALENT VENTLENGTH FEET2−1/2"dia.3" dia. 4" dia.045 110 135 160 250045 −1 to −6 59 80 107 234070 70 135 160 250070 −1 to −6 59 80 108 2140 − 2000090 50 100 125 225(0 − 609 m) 090−1 26 42 72 204110* 30 70 125 200110* −1, −2 n/a 32 72 179135** n/a n/a ***125 180135** −1, −2 n/a n/a 61 160045 110 135 160 250045 −1 to −6 59 80 107 234070 70 135 160 250070 −1 to −6 59 80 108 2142001 − 4500 090 50 100 125 225(610 − 1371m)09−1 26 42 72 204110* 20 70 125 200110 −1, −2 n/a 32 72 179135** n/a n/a ***90 180135** −1, −2 n/a n/a 61 160045 110 135 160 250045 −1 to −6 59 65 77 234070 70 135 160 250070 −1 to −6 59 65 78 2144501−7500090−1 26 42 72 204(1372−2286 m) 090 30 100 125 225110* n/a 70 125 200110* −1, −2 n/a 32 72 179135** n/a n/a ***90 180135** −1, −2 n/a n/a 61 160045 110 135 160 250045 −1 to −6 59 65 77 234070 70 135 160 250070 −1 to −6 59 65 78 2147501 − 10000 090 n/a 100 125 225(2287 − 3048m)090−1 26 42 72 204110* n/a 70 125 200110* −1, −2 n/a 32 72 179135** n/a n/a ***90 180135** −1, −2 n/a n/a 61 160*G43UF−48C−110 <strong>and</strong> G43UF−60C−110 must have 90° street ell (supplied)installed directly into unit flue collar.**G43UF−60D−135 must have 3" to 2" reducing ell (supplied) installed directlyinto unit flue collar.***90° elbows used in configuration of G43UF−60D−135 vent, must be limitedto 3" sweep elbows.TABLE 13MAXIMUM VENT PIPE LENGTHS NON−DIRECT (1 PIPE)MAXIMUM EQUIVALENT VENTLENGTH FEETG43UFALTITUDEMODEL2" dia.2−1/2"dia.3" dia.4"dia.045 110 135 160 250045 −1 to −6 104 120 137 234070 70 135 160 250070 −1 to −6 84 110 138 2140 − 2000090 50 100 125 225(0 − 609 m) 090−1 26 42 72 204110* 30 70 125 200110* −1, −2 n/a 32 72 179135** n/a n/a ***125 180135** −1, −2 n/a n/a 61 160045 110 135 160 250045 −1 to −6 104 120 137 234070 70 135 160 250070 −1 to−6 84 110 138 2142001 − 4500090 50 100 125 225(610 − 1371 m) 090−1 26 42 72 204110* 20 70 125 200110* −1, −2 n/a 32 72 179135** n/a n/a ***90 180135** −1, −2 n/a n/a 61 160045 110 135 160 250045 −1 to −6 59 65 77 234070 70 135 160 250070 −1 to −6 59 65 78 2144501 − 7500 090 30 100 125 225(1372 − 2286m)090−1 26 42 72 204110* 20 70 125 200110* −1, −2 n/a 32 72 179135** n/a n/a ***90 180135** −1, −2, n/a n/a 61 160045 110 135 160 250045 −1 to −6 59 65 77 234070 70 135 160 250070 −1 to −6 59 65 78 2147501 − 10000 090 n/a 100 125 225(2287 − 3048m)090−1 26 42 72 204110* n/a 70 125 200110* −1, −2 n/a 32 72 179135** n/a n/a ***90 180135** −1, −2 n/a n/a 61 160*G43UF−48C−110 <strong>and</strong> G43UF−60C−110 must have 90° street ell (supplied)installed directly into unit flue collar.**G43UF−60D−135 must have 3" to 2" reducing ell (supplied) installed directlyinto unit flue collar.***90° elbows used in configuration of G43UF−60D−135 vent, must be limitedto 3" sweep elbows.Page 21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!