Commissioning and operationTerminal box in the engine room / interface with light-emitting diodes + keysMAN Marine DieselTESTRESETSerial data activityTYP BE3The terminal box with light-emitting diodes functions at the same time as an engine roommonitoring panel.If an alarm is issued, the corresponding light-emitting diode lights up. The following relaysare activated on the diagnosis unit:D Engine slow down (main alarm) = reduction of engine speedD Horn = acoustic alarmD Group alarm = collective fault indicationThe keys are intended for:D Horn offSwitches off the alarm horn and the integrated buzzerD Flashing light off, transition to continuous light / test of light-emitting diodesSwitches off the flashing signal of the relevant warning lamp, i.e. the flashinglight switches to continuous light. Before the flashing signal is cleared, thealarm horn must be switched off.D ResetClearing the alarm message (red warning lamp goes out)Requirement for clearing an alarm message is:– Pressing the keys “Horn off” and “Test” in that order– Removing the cause of the alarm48