12100 OWNER'S MANUAL9163 Ionization SensorThe 9163 (<strong>System</strong> Sensor 1551 B) uses a sensor address between 0l and 99 on an addressable devicecircuit. The 9163 is regularly scanned by the control unit and checked for its current sensor and chamberstatus. These statuses are reported by device location to the control unit. The control unit will interpretand respond to the analog data as programmed. Each time the 9163 is scanned the integral red visibleLEDs will flash. In the case of an alarm condition the red LEDs will illuminate and latch on. The 9163allows programmable analog sensitivity. Requires a 9155, 9156, 9181, 9297 or 9299 base (<strong>System</strong>Sensor B501B, B501BH, B501, B524RB or B524BI).9186 Low Profile Ionization SensorThe 9186 Low Profile Ionization Sensor (<strong>System</strong> Sensor 1251) uses an address between 01 and 99 onan addressable device circuit. The 9186 is regularly scanned by the control unit and checked for itscurrent sensor and chamber status. These statuses are reported by device location to the control unit.The control unit will interpret and respond to the analog data as programmed. Each time the 9186 isscanned the integral red visible LEDs will flash. In the case of an alarm condition the red LEDs willilluminate and latch on. The 9186 allows programmable analog sensitivity. Requires a 9189, 9296 or9298 base (<strong>System</strong> Sensor B210LP, B224RB or B224BI).9187 Low Profile Photoelectronic SensorThe 9187 Low Profile Photoelectric Sensor (<strong>System</strong> Sensor 2251) uses an sensor address between 01and 99 on an addressable device circuit. The 9187 is regularly scanned by the control unit and checkedfor its current sensor status. The control unit will interpret and respond to the analog data asprogrammed. Each time the 9187 is scanned the integral red visible LEDs will flash. In the event of analarm condition the red LEDs will illuminate and latch on. The 9187 allows programmable analogsensitivity. Requires a 9189, 9296 or 9298 base (<strong>System</strong> Sensor B210LP, B224RB or B224BI).NOTE: The devices are set at the factory for address 00. This is a default code. Duringinstallation set address to the predetermined address code.9155, 9156 or 9181 Addressable/Analog BasesThe 9155 or 9181 (<strong>System</strong> Sensor B501B or B501) base is a standard design for use with anaddressable/analog sensor. Provides connection to an optional remote LED. The 9181 is flange-less forspecial mounting applications.The 9156 (<strong>System</strong> Sensor B501BH) audible sensor base is designed for use with an addressable/analogsensor. The 9156 provides means to obtain a local audible alarm at the specific sensor location. Oncethe 9156's associated sensor has latched into the alarm state, the integral horn in the 9156 will sound. Itwill remain on until the sensor is successfully reset. A regulated power supply is required for the integralhorn.9189 Low Profile Addressable/Analog BaseThe 9189 (<strong>System</strong> Sensor B210LP) Low Profile base is used with the 9186 and 9187 addressable/analogLow Profile sensors. Provides connection to an optional remote LED.P/N 447051 Issue I Rev. C V-12

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!