11.07.2015 Views

drawings

drawings

drawings

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

REFERENCE SIDEOPPOSITE SIDE1.NOT USED.METAL STUDS5/8" GYPSUM BOARDUSE 5/8" WATER RESISTANT GYPSUM BOARD AT WET AREAS UNO2.3.4.5.6.7.USE 1/2" GYPSUM BOARD ON NON-RATED PARTITIONS UNO.USE 5/8" TYPE X GYPSUM BOARD ON FIRE RATED PARTITIONS.REF ROOM FINISH SCHEDULE FOR ROOMS THAT RECEIVE FRP.CONTINUE FINISH MATERIAL TO A MINIMUM OF 4" ABOVE SUSPENDED CEILING SYSTEMS UNO.REF PARTITION KEY SYMBOL FOR STUD THICKNESSES.WHERE NO CEILING IS INDICATED CONTINUE FINISH TO DECK UNO. MAINTAIN CLEARANCE BELOW STRUCTURE PER CAPTURE TRACK DETAILS710 West Roselawn DriveRogers, Arkansas 72756Phone: 479.636.3545Fax: 479.636.1209Architect of RecordBradley J. Phillips8.C\a060-ptY9.10.11.STUD PARTITIONS REQUIRING A FIRE RATING OF ONE HOUR SHALL COMPLY WITH UL#U465 OR UL #U442. MASONRY PARTITIONS REQUIRING ONE HOUR FIRE RATING SHALL COMPLY WITH UL#U905.STUD WALLS RECEIVING PLYWOOD SHALL BE 22 GAUGE OR HEAVIER.MAXIMUM HEIGHT OF NON LOAD BEARING WALL ABOVE HEADER TO BE 20'-0".{REF SPECIFICATIONS FOR LATERAL BRACING OF STUD PARTITIONS.}STIPULATION FOR REUSE12.NOT USED.13.USE GYPSUM BOARD BEHIND ALL FRP BOARD UNO.14.WHERE NO CEILING IS SCHEDULED, STOP 1/2" PLYWOOD SUBSTRATE AT 10'-0" AFF.15.PROVIDE FIRE BLOCKING AT FLOOR AND ROOF LEVELS, CONCEALED SPACES BETWEEN STAIRWAY STRINGERS, PENETRATIONS IN FLOOR/CEILING ASSEMBLIES AND OTHER LOCATIONS AS REQUIRED BY CODE.16.ROOMS THAT HAVE 5/8" IMPACT RESISTANT GYP BD TO 48" AFF NEED 5/8" GYP BD ABOVE 48" AFF. REF A7 FOR LOCATIONS.17. NOT USED.DETAIL:GENERAL REMODELPLAN:LETTER INDICATES PARTITIONTYPEREF PLANS AND SHEET A6REFERENCE SIDEOPPOSITE SIDE1 - 1 5/8" METAL2 - 2 1/2" METAL3 - 3 5/8" METALNUMBER INDICATES STUDHEIGHTNO NUMBER INDICATESSTUD HEIGHT TO BOTTOMOF ROOF DECK TYPNUMBER INDICATES STUD SIZE AS FOLLOWS:6 - 6" METAL8 - 8" CMU12 - 12" CMU1 HOUR RATED GYPSUM BOARD (NEW) UL#U442OR U465,1 HOUR RATED CMU (NEW) UL#U905STORE NO.JOB NUMBER:NON-RATED GYPSUM BOARD WALL (NEW)ACOUSTICAL INSULATION FULL WALL THICKNESS (NEW)CHAIN LINK FENCE (NEW)COOLER/FREEZER WALL (NEW)INDICATES (NEW) 48" HIGH PLASTIC LAMINATE WAINSCOT OR PROTECTIVE SURFACE WAINSCOT UNO.INDICATES (NEW) 48" HIGH PLYWOOD WAINSCOT WITH 2x8 WOOD BASE AND DB5 BASE UNOISSUE BLOCKEXISTING 1 HOUR RATED GYPSUM BOARD TO REMAINEXISTING PARTITION OR WALL TO REMAINCMU WALL (NEW)EXISTING WALL TO BE DEMOLISHEDCHAIR RAIL FURNISHED BY WALMART, INSTALLED BY G.C.NON-RATED GYPSUM BOARD WALL (NEW) (GROCERY PREP AREAS) WITH SILL SEALERCHECKED BY:DRAWN BY:PROTO:188PROTO CYCLE:11-19-10DOCUMENT DATE:02-09-11{INTERIOR NON-LOAD BEARING PARTITION HEADER SCHEDULE}HEADER LENGTH2' TO 6'6' TO 8'8' TO 10'10' TO 12'12' TO 14'14' TO 16'16' TO 18'18' TO 26'HEADER MEMBERS(2) 6" x 18 GAUGE(2) 6" x 16 GAUGE(2) 6" x 14 GAUGE(2) 8" x 18 GAUGE(2) 8" x 16 GAUGE(2) 8" x 14 GAUGE(2) 10" x 14 GAUGE(2) 12" x 16 GAUGEMINIMUM EFFECTIVE PROPERTIES PER STUDIx = 2.042 Sx = 0.670Ix = 2.518 Sx = 0.839Ix = 3.094 Sx = 1.031Ix = 4.134 Sx = 1.033Ix = 5.110 Sx = 1.277Ix = 6.303 Sx = 1.576Ix = 12.325 Sx = 2.456Ix = 15.730 Sx = 2.334DOUBLE MTL STUD AT JAMBSMETAL STUDPRINTED: 8/4/2011 3:27 PM BY: Brenda Garrison LAST SAVED: 8/2/2011 1:11 PM BY: LukeSpurgeone:\2010xxx\2010-0452 ruston_la\4condoc\188 (general remodel-2)\arch\sheets\a060.dwgBOX BEAMPC 18 GA TRACK{SECTION B}BOTTOM TRACKTOP TRACK2 STUD HEADERSFINISH AS INDICATEDBOTTOM TRACKVARIES{SECTION A}METAL STUD HEADERPC 18 GA TRACK WITH (3) #10 TEKSCREWS EACH SIDE TO HEADER AND (6) #10 TEK SCREWS TOJAMBMETAL STUD JAMBNOT FORCONSTRUCTIONSHEET:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!