11.07.2015 Views

drawings

drawings

drawings

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CIRCUIT SCHEDULEGENERAL REFRIGERATION ELECTRICAL NOTES1. PROVIDE ALL CONDUIT AND WIRE AS INDICATED ON DRAWING. NEATLY BUNDLECIRCUITS AND CLEARLY TAG AND LABEL EACH CIRCUIT WITH BRANCH CIRCUITDESIGNATION AND REFRIGERATION SYSTEM NUMBER FOR TERMINATION BYREFRIGERATION CONTRACTOR.2. COORDINATE ALL WORK WITH REFRIGERATION CONTRACTOR PRIOR TOINSTALLATION.3. KEEP PENETRATIONS THROUGH COOLER AND FREEZER BOXES TO A MINIMUM.ROUTE ALL CONDUITS SERVING FREEZERS AND COOLERS ON INSIDE OF BOX.4. UNDERSLAB CIRCUITS SHALL NOT BE ROUTED UNDER WALK-IN FREEZERS ANDSHALL BE ROUTED ABOVE REFRIGERANT LINES WHERE THEY CROSS.GROCERY EQUIPMENT SCHEDULENO.MISC. GROCERY EQUIPMENT SCHEDULEMG21ELECTRICAL EQUIPMENT SCHEDULE NOTESA.B.C.D.E.F.DESCRIPTIONWASTE COOKING OIL TANKPROVIDE CORROSION RESISTANT PLUG, CONNECTOR, AND WEATHERPROOF BOOTS. CONNECTOR AND WEATHERBOOTS SHALL BE FROM THE SAME MANUFACTURER.PROVIDE MATCHING CORD AND MALE PLUG.WIRING DEVICE ON DROP CORD FROM CEILING. REFER TO SUSPENDED DROP CORD DETAILS.WIRING DEVICE CIRCUITED TO SHUNT-TRIP BREAKER.PROVIDE WEATHERTIGHT FLEX CONDUIT AND WIRING FROM DISCONNECT SWITCH OR JUNCTION BOX TO EQUIPMENT KNOCKOUT OR ELECTRICAL CONNECTION POINT.MAKE FINAL CONNECTIONS TO EQUIPMENT.MANUFACTURERCLEANSTARMODEL NO.2500-CWVOLT/PH120/1AMPSHP1/3VATERMINATIONSIMPLEX; NEMA 5-20RMTG. HT.+48"NOTESNOT USED{ALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATION AND COPPER CONDUCTORS WITH TYPE THHN/ THWN-2 INSULATION. WHERE ALUMINUM CONDUCTORS ARE ALLOWED PER SPECIFICATIONS AND FOR TERMINATION OR INSULATION TYPES RATED LESS THAN 75 DEG C, MODIFY SIZES ACCORDING TO NFPA 70.}ANY CONDUIT INSTALLED AT EXISTING WALLS REQUIRING IT BE SURFACE-MOUNTED SHALL BE ATTACHED WITH PROPER STAND-OFF SEPARATION TO ALLOW FOR CLEANING OF WALL SURFACES.5. ON GROUPS OF THREE OR MORE REFRIGERATED CASES WITH ELECTRIC DEFROST,REFRIGERATION CONTRACTOR SHALL CONNECT CASES TO CREATE A THREE-PHASEHEATER CIRCUIT. HEATER LOADS SHALL BE BALANCED BETWEEN PHASES AS EVENLYAS POSSIBLE (REF CASE DEFROST WIRING DETAIL).6. ROUTE REFRIGERATED CASE AND COIL FAN, LIGHTS, ANTI-SWEAT AND DEFROSTBRANCH CIRCUITS TO WIREWAYS PROVIDED AT REFRIGERATION EQUIPMENT. PROVIDEAN ADDITIONAL 6 FEET OF CONDUCTOR AT REFRIGERATION EQUIPMENT TO ALLOWADEQUATE LENGTH FOR TERMINATION. FINAL TERMINATION AT REFRIGERATED CASESBY REFRIGERATION CONTRACTOR.STIPULATION FOR REUSEG.PROVIDE CORROSION PROOF PLUGS AND RECEPTACLES FOR EQUIPMENT SPECIFIED ON ELECTRICAL EQUIPMENT SCHEDULE NOTES.H.J.K.IF EQUIPMENT IS FURNISHED WITH A DIFFERENT PLUG, E.C. SHALL CUT OFF OLD PLUG AND INSTALL NEW PLUG AS SPECIFIED.VERIFY EXACT POINT(S) OF CONNECTION(S) AND FIELD WIRING REQUIREMENTS WITH EQUIPMENT INSTALLER.IF NOT FURNISHED WITH EQUIPMENT, FURNISH AND INSTALL 6'-0" LONG SJO CORD WITH GROUNDING CONDUCTOR, SIZED AS FOLLOWS:5 CONDUCTORS: #8W.(28A), #10W.(20A), #12W.(16A), #14W.(12A). 4 CONDUCTORS: #4,(60A), #8W.(35A), #10W.(25A), #12W.(20A), #14W.(15A).3 CONDUCTORS: #8W.(40A), #10W.(30A), #12W.(25A), #14W.(18A). FURNISH AND INSTALL GROUNDING TYPE ATTACHMENT CAPCAP ON CORD FOR USE WITH INDICATED RECEPTACLE OR CONNECTOR.SEE ELECTRICAL SPECIFICATIONS FOR RECEPTACLE, CONNECTOR, AND PLUG INFORMATION. PROVIDE AS REQUIRED.CORD AND PLUG FURNISHED WITH EQUIPMENT.4CASE CONNECTION WIRINGNTSREFRIGERATED CASE WIRING NOTES1. PROVIDE CONDUIT AND WIRE FOR REFRIGERATED CASE FANS,LIGHTS AND ANTI-SWEAT HEATERS TO WIREWAY AT REFRIGERATIONEQUIPMENT, UNLESS NOTED OTHERWISE. WIRE SIZE AS INDICATED INSCHEDULE. FINAL TERMINATIONS AT CASE AND AT REFRIGERATIONEQUIPMENT BY R.C. REF CASE CONNECTION WIRING DETAIL.2. REFRIGERATED CASE WIRING COMPARTMENT REPRESENTED ONDRAWING BY RECTANGULAR BOX.COMPRESSORHOUSE #2(ON ROOF)RACK C150 KVAXFMRRACK D480VSERVICEPNL3. CIRCUITS FOR REFRIGERATED CASES SERVED BY UNDERSLABREFRIGERATION PIPING ARE TO BE ROUTED UNDERSLAB. REFER TOCASE CONNECTION WIRING DETAIL.4. ALL UNDERSLAB CONDUITS SHALL BE 3/4" MIN.5. CIRCUITS FOR REFRIGERATED CASES SERVED BY OVERHEADREFRIGERATION PIPING ARE TO BE ROUTED DOWN FROM STRUCTUREAT THE SAME LOCATION AS THE REFRIGERATION PIPING AND EXTENDEDTO THE FIRST CASE IN EACH SYSTEM BY THE E.C. WIRE AND CONDUITFOR SLAVE WIRING BETWEEN CASES SHALL BE PROVIDED BY THE R.C.ELECTRICAL KEYNOTESRUSTON, LOUISIANASTORE NO. 0023-201GENERAL REMODEL2010-0452JOB NUMBER:ISSUE BLOCKLCU07-14-11 PLAN REV. #108-05-11 ADDENDUM #1CH2A16.492EC SHALL COORDINATE WITH GENERALCH2B208VSERVICE PNLCONTRACTOR AND ARCHITECTURALDEMOLITION PLANS THE EXTENT OFELECTRICAL DEMOLITION. REMOVECONDUITS AND WIRES ALL THE WAYBACK TO ORIGINATING JUNCTIONBOXES OR PANELBOARDS. DEMOLITIONSHALL NOT AFFECT ACTIVE CIRCUITS.LABEL DEMOLISHED CIRCUIT(S) INPANELBOARDS AS "SPARE".COORDINATE EXACT REQUIREMENTS WITH4EXISTING CONDITIONS PRIOR TO BID.EXISTING POWER (NOT SHOWN) SHALL REMAINCHECKED BY:JEEDRAWN BY:TJPPROTO:188PROTO CYCLE:11-19-10HALLWAYEXISTING DOORS WITH LED LIGHTING TO REMAINDOCUMENT DATE:02-09-11GROCERY SALESEF ETRDELI FREEZERDELI PREPSEAFOODPREPDELI COOLERL5D3DEPT. 82208VSERVICE PNLLCU-CH3DAIRY COOLER225 KVAXFMRCH3225 KVAXFMRSERVICE DELI480V SERVICEPNLRACK EEXISTINGSTACKEDDISCONNECTS16.49216.492 16.49216.492EXISTING POWER (NOT SHOWN) SHALL REMAINRACK E CONTROLLERCOMPRESSORHOUSE #3(ON ROOF)CAKE DECORATING16.492BAKERYNOTE: REFRIGERATION CONTRACTOR IS RESPONSIBLE FOR ALL FINAL REFRIGERATION ELECTRICAL TERMINATIONS TO REFRIGERATION EQUIPMENT.SUBWAYS:\Wal-Mart\W447\D\W447GE2 2 Aug 2011 - 5:02 pmREAR GROCERY POWER PLAN1/8"=1'-0"RFRONT GROCERY POWER PLAN1/8"=1'-0"16.492BEXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS.EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGHKNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIRRELATED FIELD. THE FAILURE TO ACQUAINT THEMSELF WITH THISKNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OFPERFORMING THE WORK PROPERLY. NO ADDITIONAL COMPENSATIONSHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUETO FAILURE TO FAMILIARIZE WORKERS WITH THISKNOWLEDGE.GROCERYPOWERPLANSHEET:GE2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!