VISION CENTER208/120V11.19.10(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)PANELBOARD NOTES ()TERMINATE GROUND ON ISOLATED GROUND BUS.INSTALL LOCKING DEVICE (LOCK-OFF FOR MAINTENANCE). LOCKING DEVICE SHALL BE UL LISTED. MANUFACTURER SHALL MATCH EXISTING PANELBOARD MANUFACTURERINSTALL LOCKING DEVICE (LOCK-ON FOR CRITICAL LOAD).GFI BREAKER.GFEP CIRCUIT BREAKER.REFER TO ONE-LINE DIAGRAM FOR AVAILABLE FAULT CURRENT FOR INTERRUPT RATINGS.REFER TO ONE-LINE DIAGRAM FOR WIRE SIZES.FACTORY WIRED TO LOAD.BREAKER SHALL BE HIGH MAGNETIC TYPE.NEW PNLBD TO REPLACE EXISTING PNLBD WITH THE SAME NAME. NEW PNLBD POPULATION WAS DETERMINED BY ORIGINAL CONSTRUCTION DRAWINGS. E.C. SHALL VERIFY THAT ALL EXISTING BRANCH CIRCUITS ARE EXTENDED TO NEW PNLBD LOCATION. E.C. SHALL VERIFY CONDITION OF EXISTING BRANCH CIRCUIT CONDUIT AND WIRE TO EXTEND PRIOR TO USE, TO INSURE THAT THEY MEET ALL U.L. RATINGS AND REPLACE AS REQUIRED.ROUTE CIRCUIT THROUGH "SWEATMISER PNLBD"EN04CONDUCTOR SIZE HAS BEEN INCREASED FOR VOLTAGE DROP. SIZE EQUIPMENT GROUNDING CONDUCTOR PROPORTIONATELY PER NEC.LOCATION: ELECTRICAL ROOM #1SERVES: GENERAL POWERTWO SECTIONS: 225A SUB-FEED LUGS111315171923252729333537394143L1F13592131DESCRIPTIONSPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONSEXISTING LOAD(13)EXISTING LOAD(13)SPACE AND PROVISIONSEXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)SPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONS 20 10.18SPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONSWIRE BRKR PL202020 1202020202020202020120 1202020 1202020 1202011111111111111110.000.000.720.720.900.000.000.00A0.001.880.600.360.000.540.180.00PANELBOARD(EXISTING)0.000.540.720.720.900.000.00KVAB0.001.880.541.081.390.720.180.000.600.720.360.360.00C0.000.600.721.081.390.72120/208V, 3PH, 4W225A MAIN LUGS ONLYPL BRKR WIRE DESCRIPTION111 20111 20111 20111121 20EXISTING LOAD(13)1 20EXISTING LOAD(13)0.36 1 20HIRING KIOSK(1)1 20 HIRING KIOSK(1)1 20 LPTV GM RECEIVING112020202020202020202020202010,000 AICGROUND BARISOLATED GROUND BARSPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONSEXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)DATA CABINETEXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)SPACE AND PROVISIONSSURFACE MOUNT2468101214161820222426283032343638404244NOTE11.19.10 EN09{ARRONE-LINE DIAGRAM LEGEND11.19.10 ES05NEW EQUIPMENTEXISTING EQUIPMENTEQUIPMENT TO BE DEMOLISHEDNOTE:ALL OF THE ELECTRICAL DEVICES SHOWN ON THE RISER DIAGRAM AREEXISTING AND ARE BASED UPON AS-BUILT DRAWINGS. E.C. SHALL VERIFYTHE EXACT EXISTING CONDITIONS, SIZES AND LOCATIONS OF EQUIPMENTPRIOR TO ROUGH-IN. THIS RISER IS SHOWN FOR INFORMATIONAL PURPOSESONLY AND ANY NEW DEVICES ARE SHOWN IN BOLD AND ARE NOTED. DURINGCONSTRUCTION, THE STORE SHALL STAY OPEN FOR BUSINESS. ANYNECESSARY POWER DOWNTIME SHALL BE SCHEDULED AND APPROVED BYWALMART CONSTRUCTION MANAGER.STIPULATION FOR REUSE(13)(14)(15)(16)(17)(18)(19)(20)(21)(22)(23)(24)(25)EXISTING CIRCUIT TO REMAIN.ROUTE CIRCUIT THROUGH NEW CONTACTORPROVIDE INTERLOCK WIRING WITH EXHAUST HOOD ANSUL SYSTEM.CIRCUIT TO BE RELOCATED FROM EXISTING PANELBOARD.PROVIDE LUG ADAPTERS AS REQUIRED.HACR CIRCUIT BREAKER.EXISTING CIRCUIT BREAKER TO REMAIN. VERIFY CONDITION OF CIRCUIT BREAKER TO ENSURE THAT IT IS OPERATIONAL AND MEETS ALL U.L. RATINGS.ROUTE CIRCUIT THROUGH EXISTING LCU CABINET UTILIZING EXISTING RELAY AND CONTROLS. UPDATE LCU IDENTIFICATION SCHEDULE WITH LOAD IDENTIFICATION.PROVIDE HANDLE LOCK OFF DEVICE TO LOCK "SPARE" CIRCUIT BREAKER IN THE "OFF" POSITION. IF CIRCUIT BREAKER IS IDENTIFIED AS "EXISTING", FIELD VERIFY CIRCUIT BREAKER INDICATED IS NOT CONNECTED TO ANY LOAD AND UPDATE PANELBOARD CIRCUIT DIRECTORY IDENTIFYING CIRCUIT AS "SPARE".PROVIDE U.L. LISTED OVERCURRENT DEVICE TO COORDINATE AND MAINTAIN MANUFACTURER'S SERIES RATED SYSTEM.{SOLENOID OPERATED CIRCUIT BREAKER. REFER TO ENERGY MANAGEMENT PLANS FOR CIRCUIT BREAKER CONTROL.}{TRACE EXISITING CIRCUIT, IDENTIFY LOAD AND PROVIDE COMPLETE TYPEWRITTEN PANELBOARD IDENTIFICATION SCHEDULE AND PLACE ON INTERIOR OF PANELBOARD DOOR. IF CIRCUIT IS A "SPARE" THEN REFER TO PANELBOARD NOTE (21).}{PROVIDE LISTED HANDLE-TIE BETWEEN CIRCUIT BREAKERS SHARING COMMON NEUTRAL FOR SIMULTANEOUS TRIP.}4547495153555759SPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONSEXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)20 1TOTAL CONNECTEDTOTAL CONNECTEDTOTAL LOADPER NEC ARTICLE 220 FEEDER LOAD20202020120 12020111110.000.547.0458.6725.0225.020.000.60KVAKVA0.000.000.549.8181.750.000.000.60BUILDING ELECTRICAL SERVICE LOAD SUMMARYLOAD DESCRIPTIONEXISTING PEAK UTILITY LOAD @ 0.9 pfHVAC - SUMMERHVAC - WINTERLIGHTING (PER NEC-220)RECEPTACLESMOTOR LOADSLARGEST MOTOR LOADSUPPLEMENTAL ELECTRIC HEATMISCELLANEOUS EQUIPMENTREFRIGERATION EQUIPMENTEXTERIOR LIGHTINGEXISTING LOAD TO BE DELETEDTOTAL LOADTOTAL AMPACITYSERVICE AMPACITY0.000.000.548.1768.0869.5069.50BUILDING OCCUPANCY TYPE:BUILDING SQUARE FOOTAGE:0.000.600.5411111111KVA2020202020202020AMPSAMPSAMPS210,000SPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONSSPACE AND PROVISIONSEXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)EXISTING LOAD(13)ConnectedKVAN/ASERVICE DESCRIPTION:480Y/277V, 3PH, 4W0.000.000.3860.000.000.000.000.001.000.000.0061.3873.862000DemandFACTORKVAAMPSAMPS125%100%100%125%100%;50%100%125%100%100%100%125%100%DemandKVA46485052545658601160.000.000.000.4860.000.000.000.000.001.000.000.001221.481469.892000CONTACTOR SCHEDULEARCNOT USEDWARNINGLOW VOLTAGE WIRINGALL LOW VOLTAGE WIRING AND CABLE IS REQUIRED TO BE PLENUM RATED. COORDINATE PROPER CABLE TYPES REQUIRED WITH WAL-MART ALARM DIVISION AND WAL-MART CONSTRUCTION MANAGER PRIOR TO INSTALLATION.CIRCUIT SCHEDULEALL CONDUCTOR SIZES ARE BASED ON 75 DEG C RATED TERMINATIONS AND TYPE THHN/THWN-2 INSULATION; FOR TERMINATIONS OR INSULATION TYPES RATED LESS THAN 75 DEG C, MODIFY SIZES ACCORDING TO NFPA 70.20A WIRE SIZING SCHEDULEALL WIRE SIZES SHOWN ON PANEL SCHEDULES AND PLANS ARE INTENDEDTO BE MINIMUM ACCEPTABLE WIRE SIZE.THE FOLLOWING SCHEDULE IS TO BE USED TO SIZE WIRE FOR 20 AMPCIRCUITS (120 AND 277 VOLT). LENGTHS (IN FEET) ARE INTENDED TO BEMAXIMUM.FINAL CONNECTIONS: WHERE 20A BRANCH CIRCUITS HAVE #8 ANDLARGER WIRE CALLED OUT, #10AWG WIRE MAY BE USED FOR THE FINALCONNECTION (15' MAX.).ISSUE BLOCKRUSTON, LOUISIANASTORE NO. 0023-201GENERAL REMODEL2010-0452JOB NUMBER:{GENERAL NOTES:}1. E.C. SHALL ADD OR REARRANGE CIRCUIT BREAKERS WITHIN PANELBOARDS ASREQUIRED TO MATCH NEW CIRCUIT DESIGNATIONS SHOWN ON DRAWINGS.2. NEW OVERCURRENT PROTECTIVE DEVICES PLACED IN EXISTING PANELBOARDSOR DISTRIBUTION BOARDS SHALL MATCH THE TYPE AND AIC RATING OF EXISTINGOVERCURRENT PROTECTION DEVICES IN SAID BOARD.3. E.C. SHALL TRACE ALL ELECTRICAL CIRCUITS FOR ALL EXISTING ELECTRICALPANELBOARDS AFFECTED BY THE REMODEL AND IDENTIFY LOADS ON EACHCIRCUIT. PROVIDE A COMPLETE TYPEWRITTEN PANELBOARD IDENTIFICATIONSCHEDULE FOR ALL AFFECTED PANELBOARDS.4. E.C. SHALL REPAIR OR REPLACE BROKEN HINGES AND DOOR LATCHES ONEXISTING PANELBOARDS.5. ALL OVERCURRENT DEVICES ARE NEW UNLESS NOTED OTHERWISE.SPARE CAPACITY*PER UTILITY COMPANY BILLING PEAK DEMAND OF:COORDINATE ALL CHANGES TO EXISTING ELECTRICAL SERVICEAND METERING WITH UTILITY COMPANY.STORE ADDRESS:WAL-MART GENERAL REMODEL1201 N SERVICE RD ERUSTON, LA 71270AMPS1044 KW530.11NOTES:A. ALL SWITCHBOARDS AND PANELBOARDS SHALLHAVE A COMMERCIALLY PRODUCED PERMANENT LABEL APPLIED, SIMILAR TO THEABOVE, TO WARN OF POTENTIAL ARC FLASH HAZARDS, IN ACCORDANCE WITH NEC110.16 AND NFPA 70E.B. LABELING MAY BE COMPLETED BY EQUIPMENT MANUFACTURER, EQUIPMENTVENDOR/SUPPLIER, OR THE CONTRACTOR. THE CONTRACTOR SHALL VERIFY THATALL SWITCHBOARDS AND PANELBOARDS ARE PROPERLY LABELED IN THE FIELD.120 VOLT1-5 AMPS11-15 AMPS#12200 FT.6-10 AMPS 100 FT.70 FT.#10325 FT.160 FT.110 FT.#8 #6490 FT.245 FT.165 FT.770 FT.385 FT.255 FT.07-14-11 PLAN REV. #108-05-11 ADDENDUM #1UTILITY COMPANY:PHONE:EMAIL:CITY OF RUSTON318-255-1316light&power@ruston.org277 VOLT1-5 AMPS6-10 AMPS#12480 FT.240 FT.#10760 FT.380 FT.#8 #61170 FT. 1865 FT.585 FT. 930 FT.11-15 AMPS 160 FT.250 FT.390 FT.620 FT.%ARC FLASH DETAILNTSEXISTINGUTILITY TRANSFORMER480Y/277V, 3%%c, 4W SEC3000 KVAEXISTINGUTILITY TRANSFORMER480Y/277V, 3%%c, 4W SEC3000 KVACHECKED BY:DRAWN BY:JEETJPPROTO:188PROTO CYCLE:11-19-10DOCUMENT DATE:02-09-11MSWB-1EXISTINGMSWB-2EXISTING2000 AMPS 480Y/277V 3%%c 4W2000 AMPS 480Y/277V 3%%c 4W200A3P200AETR200A3P200AETR400A3P400AETR400A3P400AETR400A3P400AETR400A3P400AETR400A3P400AETR100A3P100AETR400A3P400AETR200A3P200AETR200A3P200AETR100A3P100AETR60A3P60AETR100A3P100AETR200A3P200AETR200A3P200AETR800A3P800AETR800A3P800AETREXISTING EXISTINGPNLBD PNLBDH1A277/480VH1C1277/480VEXISTING EXISTINGPNLBD PNLBDH1C2277/480VH1C3277/480VS:\Wal-Mart\W447\D\W447E4 3 Aug 2011 - 6:08 pmEXISTINGPNLBDEXISTINGPNLBDH5AH5D277/480V 277/480VEXISTINGPNLBDL5EELECTRICAL ROOM #5208/120VEXISTINGPNLBDH5C1277/480VT5E30 KVA480V-208Y/120V(EXISTING)EXISTINGPNLBDL5D2208/120VEXISTINGPNLBDH5C2277/480VEXISTINGPNLBDL5D1208/120VEXISTINGPNLBDL5BT5B208/120V225 KVA480V-208Y/120V(EXISTING)277/480VEXISTINGPNLBDCH1COMPHOUSE #1EXISTINGPNLBDL5D5208/120VPRODUCE PREPEXISTINGPNLBDCH2277/480V 277/480VCOMPHOUSE #2EXISTINGPNLBDCH3COMPHOUSE #3208/120VEXISTINGPNLBDL5D3DELI PREPT1F45 KVA480V-208Y/120V(EXISTING)EXISTINGPNLBDL1FEXISTINGPNLBDL1U1EXISTINGPNLBDL1E208/120V240/120V 208/120VUPS BATTERYT1E15KVA480V-208Y/120V(EXISTING)EXISTINGPNLBDL1D1T1D75KVA480V-208Y/120V(EXISTING)208/120VEXISTINGPNLBDL1D2208/120VELECTRICAL ROOM #1EXISTINGPNLBDTFS75 KVA480V-208Y/120V(EXISTING)EXISTING%ELECTRICAL ONE-LINE DIAGRAM1/8" = 1'-0"LFS208/120VFOOD TENANTEXISTINGPNLBDH4T277/480VPNLBDL4F208/120VT4F15 KVA480V-208Y/120V(EXISTING)ELECTRICAL ROOM #4(AUTO CENTER)EXISTINGPNLBDEXISTINGPNLBDL3D1H3A208/120VT3D75 KVA480V-208Y/120V(EXISTING)EXISTINGPNLBDL3D2208/120VELECTRICAL ROOM #3EXISTINGPNLBDH3B277/480V277/480VPHOTO LABEXISTINGPNLBDH3C277/480VEXISTINGPNLBDL3F208/120VTPL25 KVA480V-240Y/120V(EXISTING)EXISTINGPNLBDH3S277/480VT3F30 KVA480V-208Y/120V(EXISTING)EXISTINGPNLBDPL240/120VEXISTINGPNLBDH2A277/480VEXISTINGPNLBDL2E208/120VUPS BATTERYEXISTINGPNLBDL2U1240/120VT2E15 KVA480V-208Y/120V(EXISTING)ELECTRICAL ROOM #2T2B225 KVA480V-208Y/120V(EXISTING)EXISTINGPNLBDEXISTINGPNLBDL2B L2D1208/120V208/120VWIRELESSEXISTINGPNLBDL2D3208/120VNAIL TENANTEXISTINGPNLBDL2D4208/120V208/120V208/120VEXISTINGEXISTINGEXISTINGPNLBDPNLBDPNLBDLPLBTLFSPHARMACY BANK TENANT HAIR CAREEXISTINGPNLBDLW1208/120VEXISTINGPNLBDEXISTINGPNLBDL2D2208/120VEXISTINGPNLBDLN208/120VELECTRICALONE-LINEDIAGRAMANDSCHEDULESSHEET:E4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!