SINKGENERAL NOTES12 11REFER TO SHEET P1 FOR GENERAL NOTES PERTAINING TO THIS SHEET.PLUMBING KEYNOTESCLEAN ALL SUPPLYDIFFUSERS ANDEXISTING WATER HEATER ETRB15.422{}EXISTING PIPING TO REMAIN (VERIFY LOCATION IN FIELD).STIPULATION FOR REUSEPHARMACY MECHANICAL PLAN1/8"=1'-0"15 14 13 12 1 10PHARMACY STORAGEFIRE CORRIDORSECURITYROOMSPRINKLERFIRE CORRIDORUPC/INVOICINGMANAGER'S OFFICEPHOTO STORAGEEXISTING 2-1/2"CW15.4224FIXTURE STORAGEGP1.1COMPACTORTIRE & BATTERY STORAGERECEIVING-{GM }STOCKROOMEXISTING 6" SS15.422FCO ETRDEPARTMENTMANAGER'SWORKSTATIONEXISTING 6" SS15.422ELECTRICALROOM #1STOCKROOM4CLAIMSJANITORP1 M1 P1PHOTO LAB/SITE TO STORETRAININGBREAKROOMPERSONNELFIXTURESAP OFFICEBREAKROOMMANAGEMENTCUSTOMERMENCUSTOMERWOMENASSOCIATE MENASSOCIATE WOMENMARKET MANAGER'S OFFICEFIRE CORRIDORDAIRY COOLERHALLWAYDELI FREEZERDELI COOLERDELI PREPSERVICE DELIDEPT. 82RECEIVING-{GR}STOCKROOMFIRE CORRIDORRUSTON, LOUISIANASTORE NO. 0023-201GENERAL REMODEL2010-0452JOB NUMBER:CUSTOMER SERVICETOILETISSUE BLOCKELECTRICAL ROOM #4FCO ETRELECTRICALROOM #507-14-11 PLAN REV. #108-05-11 ADDENDUM #1LUBE & TIRE MOUNTING AREASECURITYEXISTING 4" SS15.422GROCERY FREEZERSTORAGEFCO ETRMAC1MEAT COOLERFEXISTING 1-1/2"CW15.422CHECKED BY:JEESALESMEAT PREPDRAWN BY:TRFEPROTO:188EXISTING 1/2"CW15.422FCO ETRP1WET DEVELOPING EQUIPMENT TO BE REMOVED BY EQUIPMENT VENDORSILVER RECOVERY UNIT TO BE REMOVED BY OTHERS. GENERAL CONTRACTOR TO CAP EXISTING DRAIN/CONNECTION AS REQUIRED.GROCERY SALESMEAT HOLDINGGROCERY COOLERICE CREAM FREEZERPROTO CYCLE:DOCUMENT DATE:11-19-1002-09-11EXISTING 6" SSPHOTO LAB ETRWATER FILTRATION SYSTEM TO BE REMOVED BY OTHERS. GENERAL CONTRACTOR TO DISCONNECT WATER LINE TO WATER FILTRATION SYSTEM AND MAINTAIN CONNECTION OF WATER LINE TO SINK.SEAFOOD COOLERSEAFOOD FREEZEREXISTING 1-1/2"CW15.42215.422SEAFOOD PREPSEASONAL SHOPEXISTING 1-1/4"CW15.422YCO ETRPHARMACYMP1EXISTING 6" SS15.422FCO ETREXISTING 1-1/2"CW15.422CART STORAGE-{GM }ELECTRICAL ROOM #3EXISTING 3/4"CWP1P1JANITORCORRIDOREXISTING 2"CW15.422EXISTING 2"CWM1PICTURE MEEXISTING 2-1/2"CW15.422CART STORAGE-{GR}4M1SUBWAYRCAKE DECORATINGBAKERYPLUMBING/MECHANICALPRODUCE PREPPRODUCE COOLERBAKERY COOLERBAKERY FREEZERBGP1ALL HVAC WORK ON THIS PROJECT IS TO BE COMPLETED BY A WALMART APPROVED CONTRACTOR.S:\Wal-Mart\W447\D\W447MP1 3 Aug 2011 - 4:41 pmGARDEN CENTERP1YCO ETROTHER INCOME-GMVESTIBULE-{GM}VISION CENTERCOURTESY DESKCASHCOUNTWOMENREGAL NAILS%MECHANICAL AND PLUMBING PLAN1" = 20'-0"MENSMART STYLEBANKWIRELESS STOREEXISTING 6" SS15.422VESTIBULE-{GR}M1OTHER INCOME-GRYCO ETRELECTRICAL ROOM #2EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS.EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGHKNOWLEDGE OF ALL DRAWINGS AND SPECIFICATIONS IN THEIRRELATED FIELD. THE FAILURE TO ACQUAINT HIMSELF WITH THISKNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OFPERFORMING HIS WORK PROPERLY. NO ADDITIONAL COMPENSATIONSHALL BE ALLOWED BECAUSE OF CONDITIONS THAT OCCUR DUETO FAILURE TO FAMILIARIZE WORKERS WITH THISKNOWLEDGE.MECHANICALANDPLUMBINGPLANSHEET:MP1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!