ELECTRICAL KEYNOTES12EXISTING POWER (NOT SHOWN) SHALL REMAIN1116.26016.451REPLACE EXISTING DEVICE AS NOTED ON PLAN. EXISTING BOX AND CIRCUITRY TO REMAIN. (UNLESS NOTED OTHERWISE).PROVIDE EMT WITH PROPERLY INSTALLED COMPRESSION OR SET- SCREW TYPE FITTINGS AND AN INSULATED GROUND CONDUCTOR FOR ALL RACEWAYS SERVING THIS ROOM TO COMPLY WITH NEC, HEALTH CARE FACILITIES.ETRETRPHARMACYETRETRWH ETRLPEXISTINGETHERNETSWITCH TOREMAINB16.47016.471FURNISH AND INSTALL NEW 20 AMP,120 VOLT CIRCUIT(S). FEED FROMPANELBOARD AS INDICATED. PROVIDE20A-1P CIRCUIT BREAKER IF NEEDED. ECSHALL MATCH TYPE AND AIC RATINGS OFEXISTING CIRCUIT BREAKERS. EC SHALLVERIFY PRIOR TO ROUGH-IN THATEXISTING PANELBOARD HAS SPARECAPACITY TO ACCOMMODATE ADDITIONALFURNISH AND INSTALL NEW 20 AMP,120 VOLT ISOLATED GROUND CIRCUIT(S). FEED FROMPANELBOARD AS INDICATED. PROVIDE 20A-1P CIRCUITBREAKER IF NEEDED. EC SHALL MATCH TYPE AND AICRATINGS OR EXISTING CIRCUIT BREAKERS. PROVIDEORANGE COVER PLATES ON ALL ISOLATED GROUNDDEVICES WITH CIRCUIT NUMBER ENGRAVED UNLESSNOTED OTHERWISE. EC SHALL VERIFY PRIOR TOROUGH-IN THAT EXISTING PANELBOARD HAS SPARECAPACITY TO ACCOMMODATE ADDITIONAL LOAD.STIPULATION FOR REUSEPHARMACY POWER PLAN1/8"=1'-0"NOT USED1'-6"DATA +24"RECEPT +18"STACKEDTYP3216.471L2EETRWIRELESS POWER PLAN1/4"=1'-0"16.W12ETHERNET CABLE:(A) FURNISH AND INSTALL JUNCTIONBOXES AND CONDUIT, AS SHOWN ON PLANSAND AS REQUIRED BY LOCAL CODES AND/ORORDINANCES.(B) ETHERNET CABLE IS FURNISHED BYOTHERS.(C) ELECTRICAL CONTRACTOR SHALLINSTALL CABLE IN POWER POLES.RUSTON, LOUISIANASTORE NO. 0023-201GENERAL REMODEL2010-0452JOB NUMBER:3'-3"3416.471L2EEF ETRISSUE BLOCK07-14-11 PLAN REV. #108-05-11 ADDENDUM #1NOT USEDCOURTESYDESKCOUNTINGCORRIDORCUSTOMER WOMENCUSTOMER MENCASHACHECKED BY:JEEEXISTING POWER (NOT SHOWN) SHALL REMAINDRAWN BY:PROTO:TJP188PROTO CYCLE:11-19-10DOCUMENT DATE:02-09-114%MONEY CENTER POWER PLAN1/4" = 1'-0"FRONT OFFICE POWER PLAN1/8"=1'-0"416.W71VOICE/DATA: FURNISH AND INSTALLAN OUTLET BOX WITH COVER AT EACHLOCATION SHOWN, AND 3/4" CONDUITWITH PULL WIRE, FROM EACH BOX TOBAR JOISTS. PROVIDE BUSHING ONEND OF CONDUIT AT BAR JOISTS. DONOT COMBINE DROPS WITH CONDUITROUTED FROM BOX-TO-BOX. INSTALLINDIVIDUAL CONDUIT TO EACH BOX.CARTSTORAGE-{GM }PROVIDE NEW COVER PLATES FOR EXISTING VESTIBULE RECEPTACLES PER SPECIFICATIONS. TYPPROVIDE NEW COVER PLATES FOR EXISTING VESTIBULE RECEPTACLES PER SPECIFICATIONS. TYPETRETRINSECTCONTROLETRETREXISTINGFIREEXISTING EAS SYSTEM PEDESTALS TO BE RELOCATED. DISCONNECT AND RECONNECT EXISTNG BRANCH CIRCUITRY AS REQUIRED, TYP.EF ETR16.470EMR1GFIEXISTING EAS SYSTEM PEDESTALS TO BE RELOCATED. DISCONNECT AND RECONNECT EXISTNG BRANCH CIRCUITRY AS REQUIRED, TYP.INSECTCONTROLETRETRETRETRCARTSTORAGE-{GR }S:\Wal-Mart\W447\D\W447E23 3 Aug 2011 - 6:07 pmTYP OF 916.2604E2GFIGFIGFIGFI 35+48"OTHERINCOME-GMGFI16.470 L3FGFITYPTYPGFIELECTRICAL ROOM #3GFI3116.W1216.W7116.470L3FGFIb16.470GFIL3Fb33+16" AND +40" STACKEDVESTIBULE-{GM}16.470L3F37INSECTCONTROL,+96"ELECTRONIC MEDICALRECORDS (EMR), +80"EXISTING PANEL LVADJUSTMENTSVISIONCENTERGM VESTIBULE POWER PLAN1/8"=1'-0"WAITING+44",PRETESTTYP 16.45110" 8"EMRCONTACTSRECORDRETENTIONSTORAGEHALLWAY16.451+54",TYP+44",TYP+44",TYPEMREMR10" 8"10" 8"10" 8"GFIEXAM #116.451GFIEXAM #216.451AWIRELESSSTOREINSECTCONTROL,+96"VESTIBULE-{GR }16.470L2D341+16"AND +40"STACKED16.47039L2D3b16.W12 TYP16.W71 TYP16.470+48"L2D3GR VESTIBULE POWER PLAN1/8"=1'-0"b37GFIELECTRICAL ROOM #2GFIEXISTINGREDBOXGFIOTHERINCOME-GRGFIGFIGFIGFIGFIGFIGFIGFIE2TYP OF 1016.260AEXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS.EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALLDRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINTTHEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMINGTHE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OFCONDITIONS THAT OCCUR DUETO FAILURE TO FAMILIARIZE WORKERS WITH THISKNOWLEDGE.ENLARGEDPOWERPLANSSHEET:E2.3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!