CEILINGLIGHTING FIXTURE SCHEDULEELECTRICAL KEYNOTESMOUNT FIXTURES IN CORNER OF RESTROOM WALL AND CEILING. INSTALL PER MANUFACTURER'S SPECIFICATIONS, TYP.NUMBER6A6B6C1742MANUFACTURERPAULUHNLDPIGUTH - CODETITEDUAL-LITEDAY-BRITENOTE: FIXTURES AND LAMPS BELOW SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR.CATALOG NUMBERFWFN240S-276384-430-4-CCCP4A-2F40-2LZW2DIDWDE232-277-1/2EB-LT-LP-WMVBVOLTS VA277 80277 80277 8027715277 58(NOTE A)LAMP (PHILIPS)ORDER NUMBERF40T12F40T12F40T126V, 5W HALOGENF32T8/TL850/PLUS/ALTOQTYMOUNTINGDESCRIPTIONSURFACEHAZARDOUS LOCATION STRIPSURFACEHAZARDOUS LOCATION STRIPSURFACEHAZARDOUS LOCATION STRIPWALLEMERGENCY LIGHTSURFACE4' SEALED STRIP16.12516.129EXISTING LIGHT FIXTURES TO REMAIN UNLESSNOTED OTHERWISE.CONNECT TO EXISTING CIRCUIT PREVIOUSLYSERVING AREA LIGHTING THAT WASREMOVED. MAINTAIN EXISTING CIRCUITCONTROL UNLESS NOTED OTHERWISE.PROVIDE CONSTANT HOT FOR EMERGENCY,EXIT, AND LOCALLY CONTROLLED LIGHTFIXTURES.RESTROOMFLOOR%LIGHT FIXTURE MOUNTINGNTS%LIGHT FIXTURE NOTES: (APPLIES TO ALL LIGHT FIXTURES)A.B.NOTE: FIXTURES AND LAMPS BELOW SHALL BE FURNISHED BY WAL-MART AND INSTALLED BY CONTRACTOR.(NOTE B)FOR FIXTURES AND LAMPS CONTACT:HUNZICKER BROTHERS AT 800-324-1026 OR HAINES, JONES & CADBURY, INC. 800-459-7099.FOR FIXTURES AND LAMPS CONTACT:LITHONIA LIGHTING, CONYERS, GA. (800) 447-2422, EXT 2902. CHERRYL BRUCEC. IF REQUIRED BY APPLICABLE BUILDING CODE, SUPPORT ALL RECESSED OR LAY-IN LIGHT FIXTURES,DIRECTLY FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE, WITH A MINIMUM OF TWO 12-GAUGEWIRES LOCATED AT DIAGONALLY OPPOSITE CORNERS. FIXTURE SUPPORT WIRES MAY BE SLIGHTLY16.14916.S04REPLACE EXISTING LIGHT SWITCH WITHOCCUPANCY SENSOR.FURNISH AND INSTALL NEW TUBE GUARDSAND CAPS ON ALL EXPOSED LAMPS IN THISAREA.STIPULATION FOR REUSELOOSE TO ALLOW THE FIXTURE TO SEAT IN THE GRID SYSTEM. ATTACH LIGHT FIXTURES TO THESUSPENDED CEILING SYSTEM TO RESIST 100 PERCENT OF FIXTURE WEIGHT ACTING IN ANY DIRECTION.NEOPRENE WASHERAND 1/4"-20 BOLTTYPPROVIDE PREMOLDEDCLOSURE STRIP TYPMETAL CANOPY DECKREF ARCHITECTURALDRAWINGSNOT USEDCOMPLETE IN ACCORDANCE WITH APPLICABLE BUILDING CODE REQUIREMENTS.FURNISH AND INSTALL MOUNTING BRACKET TO MOUNTFIXTURE TO CANOPY DECK PER THE MANUFACTURER'SRECOMMENDATIONS. DO NOT DRILL OR PENETRATE FIXTUREHOUSING. IF FIXTURE HOUSING IS PENETRATED OR DAMAGED,THE CONTRACTOR IS RESPONSIBLE FOR FIXTURE REPLACEMENT.CANOPY LIGHTING DETAILNTSCANOPY LIGHTING DETAILNTSRUSTON, LOUISIANASTORE NO. 0023-201GENERAL REMODEL2010-0452JOB NUMBER:NOT USEDISSUE BLOCK07-14-11 PLAN REV. #108-05-11 ADDENDUM #1NOT USEDNOT USEDCHECKED BY:JEEDRAWN BY:TJP4SHADE CLOTH LIGHTINGNTSTRUCK DOCK LIGHTINGNTSREAR RESTROOM LIGHTING PLAN1/4"=1'-0"PROTO:PROTO CYCLE:DOCUMENT DATE:18811-19-1002-09-11SPRINKLERTRAINING16.S04PHOTOSTORAGEEXISTING LIGHTING (NOT SHOWN) SHALL REMAINFIRECORRIDORELECTRICAL ROOM #1CLAIMSFIXTURESFIRECORRIDORTYP 16.125DEPARTMENTMANAGER'SWORKSTATIONTELZONCHARGINGSTATIONUPC/INVOICING16.S04OSBREAKROOM16.149OSMANAGER'S OFFICE16.S04STOCKROOM16.125 TYPSECURITYROOM16.S04OS16.14916.S04APOFFICE16.S04OSMANAGEMENT16.S0416.149TYP16.125OSOS16.149E1.2JANITORSITE TO STOREROSBREAKROOM16.S04ASSOCIATEWOMEN'SRESTROOM16.125TYPCUSTOMER MENEXISTING RESTROOM NEEDS CLEANING LIGHT CONTROLS TO REMAIN, TYP.S:\Wal-Mart\W447\D\W447E12 4 Aug 2011 - 12:56 pmREAR OFFICE LIGHTING PLAN1/8"=1'-0"FURNISH AND INSTALL HUBBELL ATP1500C OCCUPANCY SENSOR WITH CU277A CONTROL UNIT, IN SERIES WITH EXISTING WALL MOUNTED SWITCHING.ASSOCIATE MEN'SRESTROOM16.125TYPCUSTOMER WOMENEXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND MAY NOT REFLECT EXACT "AS-BUILT" CONDITIONS. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. CONTRACTOR SHALL CAREFULLY COORDINATE NEW WORK AND DEMOLITION WITH ALL OTHER DISCIPLINES AND EXISTING CONDITIONS.EACH SUBCONTRACTOR IS RESPONSIBLE FOR HAVING A THOROUGH KNOWLEDGE OF ALLDRAWINGS AND SPECIFICATIONS IN THEIR RELATED FIELD. THE FAILURE TO ACQUAINTTHEMSELF WITH THIS KNOWLEDGE DOES NOT RELIEVE THE RESPONSIBILITY OF PERFORMINGTHE WORK PROPERLY. NO ADDITIONAL COMPENSATION SHALL BE ALLOWED BECAUSE OFCONDITIONS THAT OCCUR DUETO FAILURE TO FAMILIARIZE WORKERS WITH THISKNOWLEDGE.ENLARGEDLIGHTINGPLANSDETAILS ANDSCHEDULESSHEET:E1.2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!