5. Serviceability limit state – <strong>Design</strong> Load Combinations1 x Q (short term)G + 0.4Q (long term)6. Deflection criteria – (determine minimum required EI)Maximum allowable defection= (span/200)= 2mmUnder short term load: ∆ max = j 2 x g 19 x ∆ LL conc2mm= 1.0 x 1.0 x 13.0x10 6 / EIRequired EI min = 6500 x 10 3 Nmm 2 /mm widthFrom TABLE 5.5, any of the following structural plywoods will be suitable:F11, 25mm, 25-30-9 (EI = 9450 x 10 3 ) Nmm 2 /mm widthF14, 21mm, 21-24-9 (EI = 6780 x 103 ) Nmm 2 /mm widthF17, 21mm, 21-30-7 (EI = 7770 x 103 ) Nmm 2 /mm widthF27, 19mm, 19-24-9 (EI = 7030 x 103 ) Nmm 2 /mm widthUnder long term load: ∆ max = j 2 x g 19 x ∆ ( DL + LL UDL )2mmEI min= 2.0 x 1.0 x (53 + 1770) x10 3 / EI= 1824 x 10 3 Nmm 2 /mm widthwhich is less than required EI under short term load not critical7. Select Suitable <strong>Structural</strong> <strong>Plywood</strong> FlooringSubject to availability, suitable structural plywoods would include:F11, 25mm, 25-30-9 (EI = 9450 x 10 3 , f’ b Z p = 2820)F14, 25mm, 25-30-9 (EI = 6780 x 103 , f’ b Z p = 2820)F17, 21mm, 21-30-7 (EI = 7770 x 103 , f’ b Z p = 2625)F27, 19mm, 19-24-9 (EI = 7030 x 103 , f’ b Z p = 3160)<strong>Plywood</strong> specification:Specify number of sheets x 2400 x 1200 x 25mm, structural plywood to AS/NZS 2269, stress grade F11,(25-30-9), CD – A bond, <strong>EWPAA</strong> / JAS-ANZ Product Certified7.7 <strong>Structural</strong> <strong>Plywood</strong> FlooringTypical structural plywood thicknesses <strong>and</strong> stress grades for a range of minimum floor imposedloadings detailed in AS/NZS 1170 are given in TABLE 7.1. Other structural plywood stress grades <strong>and</strong>thicknesses are available <strong>and</strong> alternate stress grade/thickness combinations can be designed for <strong>and</strong>specified. Full design information on using structural plywood flooring, including span tables <strong>and</strong> fixingdetails are provided in the <strong>EWPAA</strong> design manuals T&G <strong>Structural</strong> <strong>Plywood</strong> for Residential Flooring <strong>and</strong><strong>Structural</strong> <strong>Plywood</strong> for Commercial & Industrial Flooring available from the <strong>EWPAA</strong>.59

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!