The second power connection on the ESF and ES2 provides an input for a redundant backuppower supply. With two EPS1 supplies in use, should one fail, the secondary ESP1 willautomatically and seamlessly take over. The ESP1 is 2 RU and available in 120VAC or 230VACversions.The ESP1 supplies five different DC voltages to operate the ES unit. Actual values, measuredthrough the cable at the ESF, are +15.8VDC, -15.8VDC, +48.8VDC, +4.3VDC and +6.0VDC.The front panel of the ESP1 provides an on/off switch, AC input fuse, DC output fuses and LEDsto indicate proper operation. There are separate internal AC input fuses for each individualsupply in the ESP1.The connecting cable is 13AWG eight-conductor cable, terminated with NL8 connectors. Therecommended maximum cable length is five feet. The NL8 was chosen for it’s high currentcarrying capacity and ready availability.DO NOT PLUG THE ESP1 INTO SPEAKER CABINETS OR PLUG POWER AMPOUTPUTS INTO E SNAKE FRAMES!!!2.1.3 Rear panel connectionsRear panel view