12.07.2015 Views

EnteraLite Operator's Manual - Moog Inc

EnteraLite Operator's Manual - Moog Inc

EnteraLite Operator's Manual - Moog Inc

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

CHAPTER 1 - GENERAL INFORMATIONWARNING: U.S. law restricts this device to sale by or on the order of aphysician, registered dietitian, registered nurse, or other licensed practitioner.The <strong>EnteraLite</strong> ® is a rotary peristaltic enteral feeding pump (order number Z-11583-1)designed to deliver programmed doses of enteral nutrition solutions at selectable rates.This small, lightweight pump operates in any orientation, making it ideal for ambulatory use.SIZEPump Dimensions:Pump Weight:BATTERYType:Life:4.97" H x 4.47" W x 2.00" D13cm H x 11cm W x 5cm D1.30 lb. (590g)NiMH(Nickel Metal Hydride)24 hours @ 125 ml/hrCharge Time:approximately 5 hours(see * note in Chapter 2, Running on BatteryPower)Charge Level IndicatorCompact Charger 105 to 129 VAC, 60 Hz, 0.22ADISPLAYBacklit LCDOPERATING ORIENTATIONAnyFLOW RATERange:1 - 600 ml/hr<strong>Inc</strong>rement:1 ml/hr over full rangeAccuracy: ± 5%,including highviscosity solutionsDOSEMaximum:<strong>Inc</strong>rement:3000 ml10 mlVOLUME DISPLAYCurrent Dose StatusAccumulated (Pump on or off)INTERVAL FEEDInterval Feed IndicationTime To Next Feed IndicationPRIME (approximately 600 ml/hr)ALARMSChekLoad SetLow BattNo Flow InNo Flow OutNo FoodPump Won't RunPush Run To FeedERRA - ERRZDISPOSABLE SET FEATURESAutomatic Anti-free-flowDrip Chamber EliminatedProgramming errorSet not loaded properlyBattery LowUpstream occlusionDownstream occlusion,Select 8 psi (55 kPa)or 12 psi (83 kPa)Tolerance = ± 2psi (14 kPa)psi (pounds per square inch)kPa (kilopascals)Bag or set is emptyMotor slow or jammedPump unused for 2 minutesSelf-test errorACCESSORIESMulti-purpose <strong>EnteraLite</strong> ® packsMulti-position Pole Clamp (rotatable 360°)<strong>EnteraLite</strong> ® AC Adapter/ChargerWARRANTY2 yearsOPERATING ENVIRONMENT(specified per IEC 60601-1)Temperature: 50 °F to 104 °F(10 °C to 40 °C)Humidity: 30% to 75%STORAGE ENVIRONMENTTemperature: -4 °F to 149 °F(-20 °C to 65 °C)Humidity:10% to 95% noncondensingPROGRAM MEMORY RETAINEDWhen Pump is on or offAtmosphericpressure:700 hPa to 1060 hPaLIFE EXPECTANCYThe pump will survive a minimum of 5,000 loadings.At a typical use of 1-3 loads per day, this is equivalentto 5 - 10 years.1IEC 60601-1 CLASSIFICATIONSClass I and Internally PoweredBF Applied Part

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!