12.07.2015 Views

User 2 24V DG Instructions - SEA (UK)

User 2 24V DG Instructions - SEA (UK)

User 2 24V DG Instructions - SEA (UK)

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

10DOWNUP®Sistemi Elettronicidi Apertura Porte e CancelliInternational registered trademark n. 804888EnglishSELECTION OF THE SETTINGS67410756 REV 01 - 07/2012USER 2 - <strong>24V</strong> <strong>DG</strong>PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENUSPECIAL MENU FUNCTIONS TABLE USER 2 <strong>24V</strong> <strong>DG</strong>(To enter the Special Menu keep pressed UP and DOWN at the same time for 5 seconds.To exit the Special Menu pressed END or keep pressed UP and DOWN at the same time for 5 seconds)MENU SP Description SET Description Default Set valueSp. 1 Motor M1 speed30 100 Motor M1 speed75Sp. 2 Motor M2 speed30 100 Motor M2 speed75Sl.dn Slowdown speed30Sp.lr Learning speed30 100 Learning speed50Beep BuzzerN. T Motors and limit-switch inversion off Synchronized right motoroffUUUtr.optr.cl.Op1L1.Op2L2Pu OuR.strSd.o1Sd.c1Sd.o2Sd.c2Lg.bu.PushOverD sb 6D sb 200 1000 1000 1000 100DisbOp.clO.opeO.cloD sb 3D sb 50D sb 50D sb 50D sb 50alysLa pUspyOpening torque M1and amperometric sensitivityNote: By increasing the torquethe sensitivity decreaseson Synchronized left motorEnc Encoder activation On Off In On enables the Encoder reading Off3370D sbD sbpr.bl. Pre-flashingD sb OFFD sb1,2,3 Adjustable from 1s to 5sNLeaf delay setting in openingLeaf delay setting in closingM1 opening torqueM1 closing torqueM2 opening torqueM2 closing torqueReversing StrokeM1 opening slowdownM1 closing slowdownM2 opening slowdownM2 closing slowdownFlashing lamp or Buzzer outputl.onSetting from OFF to 6 secondsFrom OFF to 20 seconds settingClosing torque M1and amperometric sensitivityNote: By increasing the torquethe sensitivity decreasesOpening torque M2and amperometric sensitivityNote: By increasing the torquethe sensitivity decreasesClosing torque M2and amperometric sensitivityNote: By increasing the torquethe sensitivity decreases70707030303030La pL. O Courtesy lightY l Only during cycle active.Y l1,2,3 Courtesy light setting from1s to 4min.Ped.o Pedestrian opening 20 100 Pedestrian opening space adjustment 100OFFOpening an closingOpening onlyClosing onlyFrom OFF to 3 secondsFrom OFF to 50% of the strokeFrom OFF to 50% of the strokeFrom OFF to 50% of the strokeFrom OFF to 50% of the strokeOnly before closingFlashing lamp always onClassic flashing lightControl lampU

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!