12.07.2015 Views

User 2 24V DG Instructions - SEA (UK)

User 2 24V DG Instructions - SEA (UK)

User 2 24V DG Instructions - SEA (UK)

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

®Sistemi Elettronicidi Apertura Porte e CancelliInternational registered trademark n. 804888EnglishUSER 2 - <strong>24V</strong> <strong>DG</strong>PROGRAMMER JOLLY PARAMETERS ADJUSTMENTThe JOLLY programmer allows to keep under control and to change all parameters of the control unit without need to use thebuttons of the control unit. Compared to the on-board display, the programmer allows to view the programming instructions inthe user's language and in a non-encrypted way. In addition to the JOLLY programmer, the user can work comfortably standingup without looking at the control unit.Screen 1Language: ITScreen 2MotorEncSpeed1Speed2Available languages: IT,EN,FR,ES [ Italian, English, Spanish, French][Field, Alpha/Surf, Beta/FlipSp, Flipper]Encoder [on/off][30÷100 ] motor 1 speed adjustment[30÷100 ] motor 2 speed adjustmentThe arrowindicates that theparameter can bechanged with the +and - buttons.Screen 3Slow SpeedLearn speedSp.Decel.O1Sp.Decel.C1[30÷100 ] slowdown speed adjustment[30÷100 ] selflearning speed adjustment[Off÷100 ] motor 1 slowdown space in opening adjustment[Off÷100 ] motor 1 slowdown space in closing adjusmtentScreen 4Sp.Decel.O2Sp.Decel.C2SoftStartTorque op.M1[Off÷100 ] motor 2 slowdown space in opening adjustment[Off÷100 ] motor 2 slowdown space in closing adjustment[0÷100 ] adjusts the acceleration ramp[10÷100]% (max. motors current)Screen 5Torque cl.M1Torque op.M2Torque.cl.M2Cycle[10÷100]% (max. Motors current)[10÷100]% (max. Motors current)[10÷100]% (max. Motors current)[Secur./auto/deadman/step1/step2/two buttons]Screen 6Double leaf / Single leafPause time [0÷240]s (pausing time in seconds, 0s halfautomatic logic)LearningTimes learning [On-Off]Cycles [0÷... ] (Number of executed cycles )Screen 7PedestrianOpen delayClose delayAnti Intrusion[30÷100]% (Pedestrian opening rate)[Off÷6s]% (Leaf delay in opening)[Off÷20s]% (Leaf delay in closing)[Off,Open,Close.,op.cl.] (Implies the presence of a N.C. contact onlimit switch which if released forces the motors in closing)Screen 8Preblink [Close, Off, 0÷5s] (Only before closing, OFF from 0 to 5s)Light Time [Cycle, Off, 0÷240s] (Only during cycle, OFF from 0 to 240s)Ph.test[1,2-1-2] (Only on Foto1, only on Foto2, on both)Max Cycles[100÷100000] (Number of cycles for maintenance)67410756 REV 01 - 07/201219

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!