FLAT MOTOR DRIVEN ROLLER CONVEYOR STRAIGHT AND CURVE TECH HANDBOOKZERO-PRESSURE CONTROLS: POWER DISTRIBUTION WIRING (Continued)POWER DROPPOWER DISTRIBUTION TRUNK LINE WIRINGPOWER DISTRIBUTION TRUNK LINE WIRINGFrom the 24VDC power supply, the trunk line wiring delivers power along the side frame to each of the ZPAmodules. Depending upon the application, the trunk line cable may have single power drops or up to five powerdrops on a single cable. Three power drops are shown in the diagram above. During installation, the quickdisconnects at the ends of the power distribution trunk line must be connected to the adjacent conveyor. Thepower drops are connected to the ZPA module as shown in the diagram below.ZONE PHOTO EYEMOTORWIREBLACK WIRE CONNECTEDTO (-) TERMINALRED WIRE CONNECTEDTO (+) TERMINALPOWER WIRE<strong>FMDR</strong> TECHNICAL HANDBOOK 2014.127