FLAT MOTOR DRIVEN ROLLER CONVEYOR STRAIGHT AND CURVE TECH HANDBOOKZERO-PRESSURE CONTROLS: POWER DISTRIBUTION WIRING (Continued)E-STOP (WHEN REQUIRED)POWER SUPPLYE-STOP LOAD BREAKCONNECTORQD1CB2CB3QD2PATCH CABLESPatch cables are used to bring power from a 24VDC power supply to flat motor zones that cannot be reachedwith standard trunk line wiring. Adjacent conveyors may also be powered by using patch cables. Care must betaken not to exceed power supply capacity as well as the current limit per power supply circuit, depending uponpower supply size.TERMINATING CAPSTerminating caps are installed at each end of the power distribution trunk line to prevent accidental shock orshort circuit.NOTE: Power supply cycling is not recommended. A load break contactor should be installed after the powersupply in order to break power to the power distribution system as required.<strong>FMDR</strong> TECHNICAL HANDBOOK 2014.130