FLAT MOTOR DRIVEN ROLLER CONVEYOR STRAIGHT AND CURVE TECH HANDBOOKTROUBLESHOOTING AND REPLACEMENT PARTS: LED START-UP SEQUENCELED START-UP SEQUENCE3 LEDs are used to communicate the firmware revision of the control assembly during the start-up sequence.Each time that power is applied to the board, the green and red LEDs will turn on for one second, then the amberLED will flash on for 0.75 seconds followed by an off period. An off period of 1.5 seconds represents a decimalpoint separating major revisions from minor revisions.START-UP SEQUENCEGREENONREDONOFFAMBER0 1 2 3 4 5 6 7 8SecondsCONTINUOUSONOFFThe sequence above is an example that would represent firmware revision 1.2. The current revision for product110163 (BMC-2) is 1.1. When the red LED turns off, the start-up sequence has ended and normal operation willcommence.<strong>FMDR</strong> TECHNICAL HANDBOOK 2014.148