Fire-Lite Alarms MS-9600 Addressable Fire Control Panel

Fire-Lite Alarms MS-9600 Addressable Fire Control Panel

Fire-Lite Alarms MS-9600 Addressable Fire Control Panel

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>MS</strong>-<strong>9600</strong> Basic System ConnectionsDC Power Outputs (24 VDC)Supervise with a power supervision relay A77-716BNonresettable Power #2 - 24 VDC filtered,power-limited (3.00 amps maximum)Supervision required. Suitable forpowering annunciators.Nonresettable Power #1 - 24 VDC filtered,power-limited (3.00 amps maximum)Supervision required. Suitable forpowering annunciators.Resettable Power - 24 VDC filtered, power-limited(3.00 amps maximum) to smoke detectors (IDC).Supervision required.654321Notification Appliance CircuitsNAC #1Style Y (shown)or Style Z3.0 amps max.ELR 4.7K, ½W+ ++NAC #2Style Y orStyle Z (shown)3.0 amps max.+2 Programmable Relays &1 Fixed Trouble RelayContact Ratings:2.0 amps @ 30 VDC (resistive)0.5 amps @ 30 VAC (resistive)Contacts shown below in normalcondition (AC power with no alarm,trouble or supervisory activity).A Fail Safe Troublerelay switches to theNO position duringtrouble conditions andunder loss of all power.NC NO CEIA-232to printer orpersonal computerFor EDP-listed equipment orpersonal computer with FACPUpload/Download Utility.50 foot maximum within same room.5 4 3 2 19 8 7 6DB9FRedWhiteGreenOR13 12 11 10 9 8 7 6 5 4 3 2 125 24 23 22 21 20 19 18 17 16 15 14TERM(EIA-485)to LCD-80FTXRCVDTRGND+TB7 (option to DB-25)T R D G I I O OX CV TR ND N+ Ṉ UT+ UṮ+ACS (EIA-485)to ACS Annunc.or UDACT-F Black(power-limited,supervised) B A A Ḇ B A A Ḇ+ - + - + - + + - + + -Alarm* Trouble Supervisory*NO NC C NC NO C NO NC C + -A + A A -B+ Ḇ BshieldTB3JP3CUT TODISABLELOCALCHARGERCut this jumper to disable theFACP battery charger whenusing external charger.TB4 TB5 TB6 TB7(*CUT TOMONITOR 4XTMFJP6Factory default relay programmingas shown on circuit board )JP5TB84XTMF OPT BDJ10 J11Connectors for 4XTMF option moduleCut this jumper to enableSupervisory relay when4XTMF module is installedCut this jumper to supervisethe 4XTMF module wheninstalled (see JP10 & JP11)To disable ground fault detection,remove jumper/shunt from JP2JP2DISABLEGNDFLTJ2OPT DACTConnector for Optional 2ndSignalling Line Circuit ModuleOPT SLCJ17 J16LCD DISPLAYTB1 TB2J6 J8KEYPAD I/FSW1Flash Memory Load Enable Switch.UP is normal position for switch.DOWN position allows loading offactory software upgradesJ3<strong>9600</strong>layE.cdrCAUTION! HIGH VOLTAGECB1HOTNEUT EARTH120 VAC, 60 HZ, 3.2 amps220/240 VAC, 50 Hz, 1.6 amps+BATTERY-Battery24 VDC, 25 Amp Hour maximumJ7PS2 Keyboard InterfaceSLC LoopRefer to the SLC WiringManual for detailedinformation on wiringaddressable devicesfor Style 4, 6 and 7.10 <strong>MS</strong>-<strong>9600</strong> PN 51335:D 11/06/01

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!