12.07.2015 Views

Fire-Lite Alarms MS-9600 Addressable Fire Control Panel

Fire-Lite Alarms MS-9600 Addressable Fire Control Panel

Fire-Lite Alarms MS-9600 Addressable Fire Control Panel

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Product DescriptionOptional Modules1.7 Optional Modules1.6.3 300 Series Intelligent <strong>Addressable</strong> Devices<strong>Fire</strong>•<strong>Lite</strong>’s 300 Series Intelligent <strong>Addressable</strong> Devices are fully compatible with the<strong>MS</strong>-<strong>9600</strong> FACP. The devices must be configured for CLIP Mode operation if thecontrol panel is installed in an existing system with 300 Series devices. The address of300 Series devices cannot be set above 99. Compatible devices include:• SD300 Photoelectric Detector• SD300T Photoelectric Detector with Thermal Sensor• CP300 Ionization Detector• M300 Monitor Module• M301 Miniature Monitor Module• M302 2-wire Monitor Module• C304 <strong>Control</strong>/Relay Module• BG-10LX Manual Pull Station1.6.4 <strong>Addressable</strong> Device AccessoriesEnd-of-Line Resistor Assembly <strong>Fire</strong>•<strong>Lite</strong> P/N R-47KThe 47 kΩ End-of-Line Resistor assembly (P/N: R-47K) is used to supervise theMMF-300, MDF-300, MMF-301 and CMF-300 module circuits. The 3.9 kΩ End-of-Line Resistor assembly is used to supervise the MMF-302 module circuit. The resistorsare included with each module.Power Supervision RelayThe UL listed End-of-Line power supervision relay is used to supervise the power to 4-wire smoke detectors and notification appliances.N-ELR Mounting PlateThe N-ELR is a single End-of-Line resistor plate which is required for use in Canada.An ELR, which is supplied with each module and fire alarm control panel, is mountedto the ELR plate. Resistors mounted to the N-ELR plate can be used for the supervisionof a monitor and control module circuit.The <strong>MS</strong>-<strong>9600</strong> main circuit board includes option module connectors for the followingmodules:4XTMF Transmitter ModuleThe 4XTMF provides a supervised output for local energy municipal box transmitter,alarm and trouble reverse polarity. It includes a disable switch and disable troubleLED. A jumper on the module is used to select an option which allows the reversepolarity circuit to open with a system trouble condition if no alarm condition exists.The module plugs into connectors J10 and J11 which are located near the top center ofthe main circuit board. When the 4XTMF module is installed, Jumper JP6, on the maincircuit board, must be cut to allow supervision of the module.SLC-2 Expander ModuleThe SLC-2 Expander Module allows expansion of the <strong>MS</strong>-<strong>9600</strong> from one SLC circuitto two SLC circuits. The module plugs into connector J3 which is located in the lowerright corner of the main circuit board. The wiring for the second SLC connects toterminals located on the expander module.20 <strong>MS</strong>-<strong>9600</strong> PN 51335:D 11/06/01

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!