Annals of the Aca<strong>de</strong>my of <strong>Romania</strong>n ScientistsSeries on Engineering SciencesISSN 2066-8570 <strong>Volume</strong> 3, Number 1/<strong>2011</strong> 119DISTURBANCES IN THE POWER SUPPLY NETWORK OFBUCHAREST SUBWAY SYSTEM (PART 1)Alexandru Ionuț CHIUȚĂ 1 , Liviu Mihai SIMA 2 ,Nicoleta Doriana SECĂREANU 3Rezumat. În prezentul studiu este <strong>de</strong>scrisă problema distorsiunilor apărute în rețeauaprincipală <strong>de</strong> alimentare a metroului București (sub pământ) cauza și acțiunile, la fel șimăsurile luate pentru limitarea distorsiunilor produse. Toate acestea sunt reflectate înmăsurătorile făcute utilizând osciloscopul Fluke instalat la punctul <strong>de</strong> dispecer, urmând afi procesate.Abstract. In the present study it is exposed the problem of disturbances in the mainpower supply of Bucharest Subway (un<strong>de</strong>rground) system, the cause and their action, aswell as the measures taken to limit the disturbances produced. All this is reflected in themeasurements ma<strong>de</strong> using oscilloscope Fluke installed at the dispatch point, following tobe then processed.Keywords: power supply system, electromagnetic compatibility, disturbance, influence, disruptivevoltages1. IntroductionFor the Bucharest Subway, the problems with the disturbances in the main powersupply system exist. These problems were revealed once with the measurementsma<strong>de</strong> using oscilloscope Fluke installed at the dispatch point.1.1. Subway substations connection to electric power networkSubway substations connection to the electric power network is ma<strong>de</strong> by:a) High level short circuit currents due to strong loop network;b) All transformers of 110 kV / MV (medium voltage) of power stations have theneutral connected to earth on 110 kV - so in the City of Bucharest is ahomopolar current circulation with damaging effect on the reinforced concretebuil<strong>din</strong>gs;c) On the si<strong>de</strong> of medium voltage in the power network and consumers connectedto the medium voltage (20 kV - for example, Bucharest Subway Line II)capacitive neutral displacement occurs, with the effect on telecommunicationsystems and closed circuit television;1 Ph.D. (ABD), Eng., University ”Politehnica” of Bucharest, (inchiuta@gmail.com).2 Ph.D. (ABD), Eng., Aca<strong>de</strong>my of <strong>Romania</strong>n Scientists, (liviusima@gmail.com).3 Eng., S.C. Metroul S.A., Bucharest, 050027, <strong>Romania</strong>, (secareanu.nicoleta.doriana@gmail.com).Copyright © Editura Aca<strong>de</strong>miei <strong>Oamenilor</strong> <strong>de</strong> Știință <strong>din</strong> România, <strong>2011</strong>Watermark Protected

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!