12.07.2015 Views

Volume 3 nr 1 / 2011 - Academia Oamenilor de Stiinta din Romania

Volume 3 nr 1 / 2011 - Academia Oamenilor de Stiinta din Romania

Volume 3 nr 1 / 2011 - Academia Oamenilor de Stiinta din Romania

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Disturbances in The Power Supply Network of Bucharest Subway System 1395. Capacitive unbalance, neutral displacement, influence of CCTV –Subway system5.1. Influence of systemElectric (power) cable lines (ECL), regardless of the treatment of neutral,influence CCTV cables because of the electromagnetic field.Influences <strong>de</strong>pend on the nominal voltage of electric cable lines (20 kV),distances of ECL and CCTV cables.Electromagnetic influences <strong>de</strong>pend on the current value of groun<strong>din</strong>g, treatment ofneutral and homopolar current component (e.g. Harmonics of or<strong>de</strong>r 3k = 3, 6, 9,12, ...).Unbalance exists even at normal operating regime on the non-transposed lines.Unbalance current is much smaller than the single-phase short circuit if ECL hasthe neutral groun<strong>de</strong>d.Influences on telecommunications lines have two aspects: the risk of acci<strong>de</strong>nt anddisturbances.In term of risk of acci<strong>de</strong>nt – the measures that are expected to avoid the inductionof hazardous voltages in case of short-circuits, are usually sufficient for lowercurrents.In terms of disturbance - the effects of short - circuit currents, that takes very littletime, are not normally taken into account, but only in special cases.For disturbances, the asymmetry currents are important un<strong>de</strong>r normal operatingregime or groun<strong>din</strong>g currents regime, when the ECL operates longer un<strong>de</strong>rgroun<strong>din</strong>g currents regime.5.2. Neutral displacementAny movement of the neutral results in the appearance of a homopolar voltage.This voltage V is due to existence of a transversal admittance:Y , Y , Y different on the three phases:ABCVVVABC V U V U V UThese admittances are <strong>de</strong>termined by the capacities of phases from the ground.For a fully transposed line, for which capacities from the ground are equal, then:ABCCopyright © Editura Aca<strong>de</strong>miei <strong>Oamenilor</strong> <strong>de</strong> Știință <strong>din</strong> România, <strong>2011</strong>Watermark Protected

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!